5-11 ELECTRICAL SYSTEM
NOTE:
If no air bubbles are coming up from a filler port, tap the
bottom of the two or three times.
Never remove the container from the battery.
● After confirming that the electrolyte has entered the battery
completely, remove the electrolyte containers from the battery.
Wait for around 20 minutes.
● Insert the caps into the filler holes, pressing in firmly so that the
top of the caps do not protrude above the upper surface of the
battery、 s top cover.
CAUTION:
Never use anything except the specified battery.
Once install the caps to the battery, do not remove the
caps.
● Using HYOSUNG pocket tester, measure the battery voltage. The tester
should indicate more than 12.5-12.6 V(DC)as shown in the Fig. If the
battery voltage is lower than the specification, charge the battery with
a battery charger.
NOTE:
Initial charging for a new battery is recommended if
two years have elapsed since the date of manufac-
ture.
SERVICING
Visually inspect the surface of the battery container. If any signs of
cracking or electrolyte leakage from the sides of the battery have
occurred, replace the battery with a new one. If the battery termi-
nals are found to be coated with rust or an acidic white powdery
substance, then this can be cleaned away with sandpaper.