If the status LED shows red after
nox representative for assistance.
If the fan LED shows red unplug the switch and call your Mellanox representative for
assistance.
If the switch shuts down due to over-temperature, unplug the switch, wait 5 minutes
and replug in the switch. For more information See "Troubleshooting" on page 31.
3.1.1.2 Status LED
The status indicator is located on the left side of the front panel (connector side) of the unit. The
following status conditions are possible:
Table 3 - Switch Status LED Configurations
LED Configuration
Off
Solid Green
Blinking Green
Red
3.1.1.3 Fan Indicators
The fan indicator is located on the left side of the front panel (connector side) of the unit. The fol-
lowing fan status conditions are possible:
Table 4 - Fan LED Configurations
LED Configuration
Off
Green
Red
16
Mellanox Technologies
four minutes
No power to the switch.
OK – the switch is running.
All OK.
Switch is booting up.
Error – there is a problem with power output from the power supply, or there is a
thermal shut down.
There is no power to the fans.
OK – the fans are running.
Error – the fans are not operating properly. Replace the switch.