Rev 1.2
14. Interconnection Of Units
Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL
certified type DP-1 or DP-2. (Note- when residing in non LPS circuit)
Overcurrent Protection: A readily accessible Listed branch circuit overcurrent
protective device rated 20 A must be incorporated in the building wiring.
15. Suitable Enclosure
Suitable electrical, mechanical and fire enclosure shall be provided by the
end product manufacturer and or the end user.
16. UL Listed and CSA Certified Power Supply Cord
and CSA Certified, 3 - conductor, [16 AWG], terminated with a molded plug rated at
125 V, [13 A], with a minimum length of 1.5m [six feet] but no longer than 4.5m.
For European connection, select a power supply cord that is internationally
harmonized and marked "<HAR>", 3 - conductor, minimum 1.0 mm 2 wire,
rated at 300 V, with a PVC insulated jacket. The cord must have a molded plug
rated at 250 V, 10 A.
17. Do Not Use the Switch as a Shelf or Work Space.
Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space. The
rails are not intended for sliding the unit away from the rack. It is for permanent instal-
lation at final resting place only, not used for service and maintenance.
18. WEEE Directive
According to the WEEE Directive 2002/96/EC, all waste electrical and electronic
equipment (EEE) should be collected separately and not disposed of with regular
household waste.
Dispose of this product and all of its parts in a responsible and environmentally
friendly way.
14
Mellanox Technologies
For North American power connection, select a power supply cord that is UL Listed
Installation Safety Warnings