Connection/Installation (TK-C685WPE/TK-C686WPE)

Cable Connection

Connecting the alarm signal cable
Alarm input signal
Connects to sensors such as infrared sensors,
door sensors, metal sensors and manual switches.
● To prevent noise from entering the internal circuit, supply
non-voltage contact signal to the alarm input signal.
● Do not supply voltage.
● When the contact is short (MAKE) or open (BREAK) on
the menu, you can set it to Alarm.
● Supply such that the alarm signal continues for at least
more than 200 ms. The alarm signal may not be
recognized if it is less than 200 ms.
GND
Alarm output signal
Connects to alarm devices such as alarm,
indicator, light or buzzer
● Alarm output 1 signal is the contact output. When there is
an alarm, the OUT1NOP-COM will become short (MAKE)
and OUT1NCL-COM will become open (BREAK).
Rating:
Max. applied voltage
N.OPEN
COM.
Max. applied current:1 A
Contact life
N.CLOSE
● Alarm output 2 signal is an open collector output insulated
with photo coupler.
● During an alarm, it is ON.
● As this cable is polarized, be sure to connect it such that
the voltage of the + terminal is higher than that of the –
terminal.
● It will be damaged if reverse voltage is supplied.
OUT +
Rating:
Max. applied voltage:DC 20 V
22
Max. driving current:25 mA
OUT -
IN
:DC 30 V or AC 24 V
:100,000 times
Memo :
● When alarm is switched ON/OFF, a sound will be
produced from the alarm output 1 relay. If you do not want to
hear the sound, use the alarm output 2 cable. However, be
sure not to exceed the rating.
Connecting the control signal cable
The maximum connection distance with RM-P2580 is 1,200
m. (Multiple cameras can be connected on one cable for RM-
P2580 but the total length of the cable must be within 1,200
m.)
Camera terminal 1
Camera terminal 2
Camera terminal 3
● To connect correctly, connect
cables that have the same mark
A B C D
camera terminal and both
terminals of RM-P2580.
Memo :
● We recommend the use of paired cables or twisted pair
cables used in Ethernet rather than 0.61-4-core (2 pairs)
cables.
● Thickness of the cable is R0.4 mm to R1.3 mm.
● Arrange the control signal cables such that the TX+ and
TX–signals and RX+ and RX–signals are pairs.
RM-P2580
TO CAMERA Terminal
as displayed on the