Appendix; Technical Appendix; Cabling - Danish Interpretation Systems DCS 6000 User Manual

Digital conference system conference units
Hide thumbs Also See for DCS 6000:
Table of Contents

Advertisement

Danish Interpretation Systems

Appendix

Technical appendix

Cabling

CAT5e
The DCS 6000 system uses CAT5e or CAT6 FTP
or STP cables with screened RJ45 connectors.
EIA 568-B wiring shall be used.
It is important to use only FTP or STP
(screened) cables and screened RJ45 connectors
and not UTP cable, which is unscreened.
How to wire a CAT5e (EIA 568-B) Cable:
Pin Function
Connector #1 Connector #2
1
In-going +
ORG/WHT
2
In-going -
ORG
3
+48V
WHT/GRN
4
0V
BLU
5
0V
BLU/WHT
6
+48V
GRN
7
Outgoing -
BRN/WHT
8
Outgoing +
BRN
Note.
If other colour codes are used then the four
pairs are connected as follows:
Pair 1:
Pin 1 & 2
Pair 2:
Pin 3 & 6
Pair 3:
Pin 4 & 5
Pair 4:
Pin 7 & 8
The phase of the pairs must be correct and the
wiring specifications as stated in CAT5e (EIA 568-
B) have to be followed.
HD15 connector
The HD15 connector on the MU 6040 D/C and MU
6042 has the following PIN layout:
44
ORG/WHT
ORG
WHT/GRN
BLU
BLU/WHT
GRN
* Only connected on MU 6042
BRN/WHT
Connection of GM 652x to AM/MU 6040
BRN
Manual 01 18 04467
Pin
Signal
1
- Loudspeaker output
2
Speak 1 LED
3
Request 1 LED
4
ON/OFF 1 button input
5
Delegate OFF button /
*ON/OFF 2 button input
6
Optional input
7
+ Loudspeaker output
(8 ohm)
8
NC
9
*Speak 2 LED
10 + lamp
11 +5V
12 0V
13 MIC ground
14 + MIC
15
*Request 2 LED
AM/MU 6040 – HD 15
Pin Comments
10 + lamp
12 0V
13 MIC ground
14 + MIC
Appendix
Cable type
DIS type:
#2029
or according to
the specific
installation.
GM 652x – XLR 3P
Pin
Comments
4
House
3
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents