SiUS12-928_B
Step
Slide the discharge grille
3
downward to unfasten the
2 hooks at the top.
4
Remove the discharge
grille.
5
Remove the nut and
remove the outdoor fan.
Removal Procedure
Procedure
Hook
Outdoor fan
Outdoor Unit: 3MXS24JVJU, 4MXS32GVJU
(R17173)
(R10380)
 Nut size : M8
 When reassembling, align the
mark of the outdoor fan
with the D-cut section of the
motor shaft.
(R10381)
Points
13 mm
(0.51 inch)
(R17410)