Daikin SUPER MULTI NX CTXS07JVJU Service Manual page 160

Super multi nx g-series / j-series
Hide thumbs Also See for SUPER MULTI NX CTXS07JVJU:
Table of Contents

Advertisement

SiUS12-928_B
5.3.2 AC Motor (CDXS/FDXS Series)
A6
Remote
Controller
Display
Method of
The rotation speed detected by the Hall IC during fan motor operation is used to determine
Malfunction
abnormal fan motor operation.
Detection
Malfunction
The detected rotation speed does not reach the demanded rotation speed of the target tap, and is
less than 50% of the maximum fan motor rotation speed.
Decision
Conditions
 Layer short inside the fan motor winding
Supposed
 Breaking of wire inside the fan motor
Causes
 Breaking of the fan motor lead wires
 Defective capacitor of the fan motor
 Defective indoor unit PCB
Troubleshooting
Check No.04
Refer to P.192
Service Diagnosis
Be sure to turn off the power switch before connecting or disconnecting
Caution
connectors, or parts may be damaged.
Start operation.
Does the fan rotate?
NO
Turn off the power supply and
rotate the fan by hand.
Does the fan rotate
smoothly?
YES
Turn the power on and check the
fan motor voltage. (immediately
after restart)
Voltage as rated? ∗
YES
Check the capacitor's continuity.
Is there continuity?
NO
YES
Check No. 04
Check Hall IC
Is there an output?
NO
YES
Check the fan motor voltage.
Voltage as rated? ∗
YES
∗ Measure the voltage
between the red and black
lead wires of the fan motor,
and check if the maximum
voltage reaches the rated
NO
voltage.
YES
Troubleshooting for Indoor Unit
NO
Replace the fan motor or the
indoor unit PCB.
Replace the indoor fan motor.
NO
Replace the indoor unit PCB.
Replace the fan motor.
Replace the indoor unit PCB.
Replace the capacitor.
(Replace the indoor unit PCB.)
Replace the fan motor.
(R17393)