FDXS-D Series
HOME LEAVE operation is a function that allows you to record your favorite set temperature and
airflow rate. You can start your favorite operation mode simply by pressing the [HOME LEAVE]
button on the remote controller.
Detail
1. Start of Function
The function starts when the [HOME LEAVE] button is pressed in cooling mode, heating mode
(including POWERFUL operation), or while the operation is stopped. If this button is pressed in
POWERFUL operation, the POWERFUL operation is canceled and this function becomes effective.
 The [HOME LEAVE] button is ineffective in dry mode and fan mode.
2. Details of Function
A mark representing HOME LEAVE is indicated on the display of the remote controller. The indoor
unit is operated according to the set temperature and airflow rate for HOME LEAVE which were
pre-set in the memory of the remote controller.
The LED (red) of indoor unit representing HOME LEAVE lights up. (It goes out when the operation
is stopped.)
3. End of Function
The function ends when the [HOME LEAVE] button is pressed again during HOME LEAVE
operation or when the [POWERFUL] button is pressed.

"HOME LEAVE operation"

set temp.
"HOME LEAVE operation"
set temp.
Others
The set temperature and airflow rate are memorized in the remote controller. When the remote
controller is reset due to replacement of battery, it is necessary to set the temperature and airflow
rate again for HOME LEAVE operation.
Function and Control
<Cooling>
Set temp.
Normal operation
<Heating>
Set temp.
Normal operation
HOME LEAVE operation
Start
Stop
HOME LEAVE operation