Removal of Outer Panels Si121175 1. Removal of Outer Panels Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step External appearance (R2159) Remove the 4 screws of Top panel the top panel and the 6 screws of the front panel.
Si121175 Removal of Electrical Box (Pattern 1) 2. Removal of Electrical Box (Pattern 1) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step 1. Remove the connecting wires.
Page 6
Removal of Electrical Box (Pattern 1) Si121175 Step Procedure Points 2. Remove the harnesses. [S20] [S21] [S22] Disconnect the connectors for the electronic expansion valve coils. [S20] [S21] [S22]. (R16025) Remove the connector for the four way valve [S80] coil [S80]. (R11729) Disconnect the [S40]: Overload protector...
Page 7
Si121175 Removal of Electrical Box (Pattern 1) Step Procedure Points Remove the reactor lead wires. Reactor (R2170) 3. Remove the wire fixing plate. Remove the 2 screws of the wire fixing plate. Wire fixing plate (R11309) 4. Remove the electrical box.
Page 8
Removal of Electrical Box (Pattern 1) Si121175 Step Procedure Points Remove the drip proof cover. Drip proof cover (R2174) Disconnect the connector for the fan Inverter PCB motor [S70] from the inverter PCB. [S70] (R2175) Lift up the electrical box and dismount it.
Si121175 Removal of Electrical Box (Pattern 2) 3. Removal of Electrical Box (Pattern 2) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step 1. Disconnect the The US model has a connecting wires.
Page 10
Removal of Electrical Box (Pattern 2) Si121175 Step Procedure Points Disconnect the When reassembling, insert [S80] connector for the four the clamp into the hole as way valve coil [S80]. below. Clamp (R17397) (R17398) Disconnect the [S40]: overload protector connectors for the [S90]: thermistors [S90] [S92] [S93] thermistors [S90] [S92]...
Page 11
Si121175 Removal of Electrical Box (Pattern 2) Step Procedure Points Disconnect the relay connector of the compressor. (R17065) Release the clamp with pliers. (R17066) Disconnect the reactor lead wires. Reactor (R2170) Removal Procedure...
Page 12
Removal of Electrical Box (Pattern 2) Si121175 Step Procedure Points 3. Remove the electrical Shield plate box. Remove the screw of the shield plate. (R17345) Unfasten the 2 hooks and remove the shield plate. (R17346) Hook Remove the screw on the right side of the electrical box.
Page 13
Si121175 Removal of Electrical Box (Pattern 2) Step Procedure Points Remove the drip proof cover. Drip proof cover (R2174) Disconnect the connector for the fan Inverter PCB (MID2) motor [S70] from the inverter PCB (MID2). Release the fan motor lead wire from the hooks.
Removal of PCBs (Pattern 1) Si121175 4. Removal of PCBs (Pattern 1) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step 1. Remove the service monitor PCB and the main PCB.
Page 15
Si121175 Removal of PCBs (Pattern 1) Step Procedure Points Remove the drip proof plate. Drip proof plate (R6577) Disconnect the connectors [S52] [S102] from the service monitor PCB. Service monitor PCB [S52] (R6578) [S102] The figure shows the service monitor PCB. Priority room setting switch (SW4) Wiring error check switch...
Page 16
Removal of PCBs (Pattern 1) Si121175 Step Procedure Points Remove the service monitor PCB. (R6580) Lift up the main PCB. Main PCB (R2181) Disconnect the connectors [S31] [S32] [S33] [S71] [H1] [H2]. [S31] [S71] [S33] (R10362) [S32] [H1] (yellow) [H2] (blue) (R10363) Removal Procedure...
Page 17
Si121175 Removal of PCBs (Pattern 1) Step Procedure Points Disconnect the connector [E]. [E] (green/yellow) (R2184) The figure shows the main PCB. [S93] [S92] [S90] [H1] [H2] [S32] [S33] [S71] [S31] [S80] [S22] [S21] [S20] [S40] (R11310) 2. Remove the inverter PCB (MID2).
Removal of PCBs (Pattern 2) Si121175 5. Removal of PCBs (Pattern 2) Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step 1. Remove the service When reassembling, insert monitor PCB and the the base bar into the hole of main PCB.
Page 19
Si121175 Removal of PCBs (Pattern 2) Step Procedure Points Lift up the main PCB. (R2181) Disconnect the connectors [S31] [S32] [S33] [S71] [H1] [H2]. [S31] [S71] [S33] (R10362) [S32] [H1] (yellow) [H2] (blue) (R10363) The figure shows the main PCB. [S93] FU2 (3.15A) [S92]...
Page 20
Removal of PCBs (Pattern 2) Si121175 Step Procedure Points Unfasten the 2 hooks and remove the service monitor PCB. Hook Priority room setting switch (SW4) LED A Wiring error check switch LED 1 (SW3) LED 2 Forced operation [ON/OFF] LED 3 switch (SW1) LED 4 NIGHT QUIET mode setting...
Si121175 Removal of Fan Motor 6. Removal of Fan Motor Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step Remove the nut and Preparation remove the outdoor fan. Disconnect the connector for the fan motor.
Removal of Sound Blankets Si121175 7. Removal of Sound Blankets Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step Remove the 5 screws of the right side panel. Right side panel (R2191)
Page 23
Si121175 Removal of Sound Blankets Step Procedure Points Remove the sound Carefully remove the sound blanket (top upper, top blanket, which is easily inner, outer, inner). torn in the piping section. Sound blanket (top upper) Sound blanket (top inner) Sound blanket (inner) Sound blanket (outer)
Removal of Coils / Thermistors Si121175 8. Removal of Coils / Thermistors Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step Remove the screw of the four way valve coil. Four way valve coil (R2194)
Page 25
Si121175 Removal of Coils / Thermistors Step Procedure Points Peel off the putty and Place the thermistor so that pull out the thermistors. its end comes up to the end Gas pipe thermistor of the fixture. Liquid pipe Be careful not to lose the clip thermistor or fixtures for the liquid and gas pipe thermistor.
Removal of Four Way Valve / Defrost Solenoid Valve Si121175 9. Removal of Four Way Valve / Defrost Solenoid Valve Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points...
Page 27
Si121175 Removal of Four Way Valve / Defrost Solenoid Valve Step Procedure Points Disconnect the 2 The defrost solenoid valve is brazed points, first (e), only for the U.S. models. and then (f). Remove the defrost Note: Do not use a metal saw for solenoid valve.
Removal of Distributor Si121175 10.Removal of Distributor Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step Before working, make Warning sure that the refrigerant Be careful not to get yourself gas is empty in the circuit.
Si121175 Removal of Compressor 11.Removal of Compressor Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Step Remove the terminal cover. Terminal cover (R16026) Disconnect the Compressor lead wire compressor lead wires.
Page 30
Removal of Compressor Si121175 Step Procedure Points Before working, make sure that the refrigerant is Warning empty in the circuit. Be careful not to get yourself Be sure to apply nitrogen burnt with the pipes and other replacement when parts that are heated by the heating up the brazed gas brazing machine.
Page 31
Revision History Month / Year Version Revised contents 08/2012 Si121175 First edition...
Page 32
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.