1. INSTALLATION AND USE
1.2.4 Disposing of batteries
•
The crossed-out wheeled bin symbol indicates that the disposing of
batteries must not be run through the normal cycle of waste disposal.
•
Batteries must be recycled or disposed of properly.
Do not throw batteries away as part of normal refuse disposal.
•
Do no throw batteries into open flame!
1.3 CONFIGURATION
1.3.1 Configuration Mod. DPT100-B/I
The printer set up print out (see fig. 1.9) includes a range of information, and among these should be pointed
out the HEAD VOLT parameter that indicates the battery charge level, i.e., the print head battery voltage.
The printer's configurable parameters are:
D
•
Interface: RS232
, Infrared
(9)
•
IR Protocol
: Enable, Disable
•
Baud Rate: 38400, 19200, 9600
D
•
Data length: 7, 8
D
•
Parity: None
, even or odd.
•
Handshaking: XON/XOFF
•
Autofeed: CR deactivated
•
Battery: 1000 mAh, 1100 mAh, 1200 mAh, 1300 mAh, 1400 mAh, 1500 mAh, 1600 mAh, 1700 mAh,
1800 mAh, 1850 mAh
•
Standby: 1min, 5min
•
Alignment: Disabled
•
Print density: -2, -1, 0
Please note: the parameters marked with the symbol
(8)
Note: If the Interface parameter is set in infrared and flow control is required, any time
a transmission is effected a time break of one time and a half the byte transmission is needed
* SETUP DEFAULT *
HEAD TEMP. [°C]
BATT TEMP. [°C]
HEAD VOLT [V]
Interface
IR Protocol
Baud Rate
Data length
Parity
Handshaking
Autofeed
Battery
Standby
Alignment
Print Density
[PUSH] ENTER SET-UP
[FAST PUSH] EXIT SET-UP
(8)
.
D
.
D
, 4800, 2400, 1200, 600.
bits/car.
D
or Hardware
(10)
.
D
or CR activated.
D
(11)
, Alkaline
.
D
(12)
, 10 min, 30 min
, 1 h, 2h, None.
D
, Enabled.
D
, +1, +2.
1-
5
= 22.5
= 25.0
= 6.3
:RS232
:Enable
: 9600 bps
: 8 bits/chr
: None
: Xon/Xoff
: CR disabled
: 1600 mAh
: 5 MIN
: Disable
: 0
D
represent the default values.
DPT100-B/I/BT
(Fig.1.8)
(Fig.1.9)
Need help?
Do you have a question about the s'print and is the answer not in the manual?