Environmental Requirements

The DocuColor 7002/8002 will enter the Power Saver mode after 15 minutes of no activity on
the machine.
The factory default time of 15 minutes can be changed in the Tools Mode.

Ambient Temperature and Humidity

10 to 32°C, 15 to 85% RH
50 to 90°F, 15 to 85% RH
Note
Above 82°F (28°C), reduced humidity is required to maintain the specified performance.

Altitude

Normal operation: 0 to 2,500 meters (0 to 8,200 feet).
Operation between 2,000 to 2,500 meters (6,557 to 8,200 feet) may require a field
adjustment.

Illumination

Normal function (free from print quality defects) can be expected under 3,000 lx maximum.

Noise Levels

Standby
IOT Operation
Full System Operation

Ozone Emissions

m3
Not to exceed 0.015 mg/

Dust

3
0.4mg/m
or less per Environment Product Safety Manual, PS-22B008

Capabilities

Tray Capacity

All paper trays (First and Second Feeder modules) have a capacity of 2000 sheets each of 24
2
pound, 90 g/m
paper.
12-6
Continuous Noise
Impulse Noise
55 dB
N/A
78 dB
83 dB
81 dB
89 dB
DocuColor 7002/8002