Omron V680 Series User Manual page 43

V680 series devicenet id slave, antennas and id tags
Hide thumbs Also See for V680 Series:
Table of Contents

Advertisement

Attaching the End Plates
To mount an End Plate easily, first hook the bottom of the End Plate and then hook
the top on the DIN Track, pull the End Plate downwards and tighten the screw.
Recommended tightening torque: 1.2 N·m.
Mounting Interval
The V680-HAM42-DRT DeviceNet ID Slaves will generate heat if they are mounted side-by-side.
Leave space between the ID Slave of at least 10 mm.
End Plate
Use at least 2 OMRON DIN Track Spacers. (Each Spacer is 5 mm wide.)
Installation, Connections, and Wiring
10 mm min.
10 mm min.
Spacer
Spacer
Spacer
PFP-S
Section 4
End Plate
RFID System
User's Manual
41