Section 3
Functions and Operation
Start Address Higher Than End Address
The memory area between the start address and the last ID Tag address, as well as the area between
0006 hex and the end address will be write-protected.
Address
0002 hex
0003 hex
0004 hex
0005 hex
Start address
Last address
RFID System
38
User's Manual
Bit
Upper digits
1
0
0
0
0
8
0
0
1
0
0
2
0
0
0
0
0
0
0
0
0
1
0
1
0000
hex
0006
hex
0015
hex
0120
hex
7FFF
hex
Lower digits
0
0
1
1
0
0
0
0
0
0
0
0
1
0
1
5
Write-protected
Area
Write-protected
Area