Omron V750-BA50C04-US Operation Manual
Omron V750-BA50C04-US Operation Manual

Omron V750-BA50C04-US Operation Manual

Uhf rfid system reader/writer antenna v750-series
Hide thumbs Also See for V750-BA50C04-US:
Table of Contents

Advertisement

Quick Links

V750-series
UHF RFID System
Operation Manual
Reader/Writer
Antenna
V750-BA50C04-US (Mono-static Reader/Writer)
V740-HS01CA (Circular Antenna)
V740-HS01LA (Liner Antenna)
Cat. No. SRFM – 012 – A
V750 RFID READER/WRITER, ANTENNA
2006-06, REV.C
1 of 110
OPERATION MANUAL
©OMRON CORPORATION 2006

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V750-BA50C04-US and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Omron V750-BA50C04-US

  • Page 1 V750-series UHF RFID System Operation Manual Reader/Writer Antenna V750-BA50C04-US (Mono-static Reader/Writer) V740-HS01CA (Circular Antenna) V740-HS01LA (Liner Antenna) Cat. No. SRFM – 012 – A V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 1 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 2 DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. IN NO EVENT SHALL THE RESPONSIBILITY OF OMRON FOR ANY ACT EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED.
  • Page 3 ©Copyright OMRON Corporation 2006. All rights reserved. This document is protected by copyright and is intended solely for use in conjunction with the product. Notify your OMRON representative before copying or reproducing this document in any manner, for any other purpose. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C...
  • Page 4 A notification that prohibits disassembly when injuries caused by electric shocks may result. Please ensure that all cautions and prohibitions are adhered to, since non-compliance may lead to serious injury or damage, in certain circumstances. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 4 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 5 • Assembling the Units. • Connecting or disconnecting the Expansion I/O Units or Expansion Units. • Connecting or wiring the cables. • Connecting or disconnecting the connectors. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 5 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 6 ・Establish a Class D grounding (former Class 3 grounding) for metal objects placed in the vicinity of the system. ・Keep cables away from those with high voltages or heavy currents. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 6 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 7 Do not install or keep the V750-BA50C04-US in the following locations: -Locations subject to shock or vibration. -Locations subject to condensation as the result of severe changes in temperature.
  • Page 8 Properly shielded a grounded cables and connectors must be used for connection to host computer and / or peripherals in order to meet FCC emission limits. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 8 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 9: Table Of Contents

    3.1.4 Command / Response Formatエラー! ブックマークが定義されていません。 3.1.5 Command Specificationエラー! ブックマークが定義されていません。 3.1.5.1 Communication Commandエラー! ブックマークが定義されていません。 エラー! ブッ 3.1.5.2 Information of the Reader/Writer - Conditions of the Reader/Writer function クマークが定義されていません。 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 9 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 10 4.2 Web Operation...........................95 4.3 Safe Mode..........................102 5 Characteristics(Reference) ....104 5.1 Communications Range ......................104 5.2 Communications Time ......................105 APPENDIX: OUTLINE DRAWINGS..106 Reader / Writer: (V750-BA50C04-US) . 106 Antenna : ( V740-HS01LA,V740-HS01CA) Antenna Cable:........108 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 10 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 11: Feature Of V750 Series Rfid System

    Mono-static Antenna (Liner) The OMRON V750 RFID Reader (herein after denoted as the V750 Reader) uses RFID (radio frequency identification) technology to read data stored on RFID tags. The reader supports UHF (ultra high frequency) antennas, which are available separately. The reader supports multiple configurations of UHF antenna ports and transfers data to a remote computer over a network connection.
  • Page 12 It is designed to increase “basic performance of communication with tag” and “Quick and simple operability” most as a unique feature. EPC IS Middleware Ethernet OMRON OMRON V750 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 12 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 13 In addition to this, Safe Mode is also equipped so that the reader/writer can recover from the upgrade error. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 13 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 14 Properly shielded a grounded cables and connectors must be used for connection to host computer and / or peripherals in order to meet FCC emission limits. (AC adaptor) with ferrite core must be used for RF interference suppression. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 14 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 15: Installation And Usage Guide

    Metal surfaces such as desks, filing cabinets, bookshelves, and wastebaskets may enhance or degrade reader performance. Mount antennas as far as possible from metal surfaces that are adversely affecting system performance. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 15 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 16 Affected antennas may be synchronized by a separate user application using a time-multiplexing strategy. – Antenna power can be reduced by reconfiguring the RF Transmit Power setting for the reader. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 16 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 17: Authorized Antennas

    Note that in no case may the power be set higher than 32.0 dBm. Recommended Power Settings Antenna Type Short Cable/Long Cable V740-HS01CA 31.5 dBm V740-HS01LA V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 17 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 18: Reader Installation

    IMPORTANT: Be sure to remain within the rated voltage and current of the power cord and outlet. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 18 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 19: Install The Antennas

    3. Insert the M4x20 screws with spring washers and flat washers and tighten until almost flush with the wall. 4. Tighten the screws securely. Note: For best performance, mount the antenna in the horizontal orientation as pictured above. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 19 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 20: Connect The Reader

    Function Connector specifications Antenna port Connects with UHF mono-static type antenna Reverse TNC ANT1- ANT4 specified by OMRON with attachment cables. Max 4 cables can be connected to. Ethernet port Connects with the host by a commercially available RJ-45 ETHERNET 10/100Base-T cable.
  • Page 21: Antenna Port

    1.3.4 Antenna Port One to four OMRON Mono-static antennas (V740-HS01CA, V740-HS01LA) can be connected to the reader, depending on the application requirements. 1. Connect required UHF antennas to the antenna ports on the reader . IMPORTANT: Connect antennas to the antenna ports before applying power to the reader. Any antenna port not having an antenna connected to it will be disabled when the reader is powered on.
  • Page 22 * Prior to connect antenna(s) to the R/W, make sure the power is off. If antenna is connected during power-on, the R/W can not detect the antenna. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 22 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 23: Led Indicators

    ANT1 port Yellow Connecting with an antenna via ANT1 is detected. connecting (Lighting for 50ms after power ‒ on.) Means communication process is running via ANT1. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 23 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 24 (Flashing 2) long interval: 500ms ON 500ms OFF IMPORTANT: DO NOT disconnect power during startup. Disconnecting power while booting the V750 reader may result in improper startup. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 24 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 25: I/O Interface

    IN 2 Input 2 IN 3 Input 3 IN 4 Input 4 IN C Input common [配線手順] (必要工具) ①ケーブルをコネクタに結線 ※ マイナスドライバ ・ケーブル固定ネジを緩めて(左回し)、ケーブルを奥まで挿入する。 ・ケーブル固定ネジを閉めて(右回し) ②コネクタをリーダライタ本体に取付け ③取り付けネジ2本で固定 マイナスドライバ ※ケーブルのコネクタへの結線は、必ずコネクタの本体取付け前に行ってください。 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 25 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 26 Photo coupler Input voltage DC12∼24V Input impedance 2.35kΩ TYP. Input current 12V: 4.5mA, 24V: 9.8mA TYP. Wiring Wiring with input equipment Filter IN C (Common) Fuse V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 26 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 27 Output voltage Output current 20mA Wiring Wiring with output equipment Filter OUT1 OUT2 二 次 側 内 部 回 OUT3 路 OUT4 OUT C (Common) Fuse V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 27 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 28: Rs232C Interface

    Receive Data 3 Send Data 4 − − 5 − Signal Ground 6 − − 7 Request to Send 8 Clear to Send 9 − − V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 28 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 29 Signal Signal Code number number name ■Connecting to the Omron’s PLC (programmable logic controller): Serial setting is set for “flow control: none”. D-sub 9 pin male D-sub 9pin female Programmable (M2.6 screw) contact (inch screw) contact V750 R/W Logic Controller cable cable.
  • Page 30: Ethernet Interface

    RXD (-) Receive Data - (negative) − Reserved/Do not use Do not use) − Reserved/Do not use Do not use) − Reserved/Do not Use Do not use) V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 30 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 31: Specifications

    Weight ....................1.4kg (3.1 lbs) Protection ......................IP50 Antenna Dimension ............ 256 x 256 x 57mm (10.1 x 10.1 x 2.3 in) Weight ....................1.0kg (2.3 lbs) Protection ......................IP50 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 31 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 32 Supported Tag Protocols 915 MHz ..................... EPC GEN2 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 32 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 33: Functions And Control

    9.6 / 19.2 / 38.4 / 57.6 kbps 57.6 kbps Data length 7 / 8 bit 7 bit Parity Bit Even / Odd / None Even V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 33 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 34 Stop Bit 1 / 2bit 2 bit V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 34 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 35 Under Safe Mode, you can check the Status via Web browser, initialize the setting, and write firmware. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 35 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 36: Ethernet Protocol

    3. Start a Java-enabled web browser from any network-enabled PC. This PC must be configured with an IP address and subnet mask compatible with the reader’s settings. For example: V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 36 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 37 10. Use the Query page of the browser-based interface to verify the reader and antenna operation by reading tags. 11. Close the browser window. Start an application to control the reader on the network. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 37 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 38: Web Browser Function

    2.Setting Initialize Initializes following setting into factory-default setting; Set Reader, Set Communication, and Set Operation. の 3.Firmware Update Uploads or resets firmware data. 4.Help Explains the functions. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 38 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 39: Functions

    Operation window of command or Web. User Input: reads ON/OFF state by receiving the command from the host. Command registry: executes registered command series at the rising edge of input signal. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 39 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 40: Firmware Upgrade

    Communication results output: output ON/OFF signal depending on the specified judgment after communication process. 2.2.4 Firmware Upgrade You can update the firmware by specifying update files via Web browser. Updated data shall be effective upon subsequent power-ups. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 40 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 41: Communication

    Select Command prior to communication sequence. 1. Prevention of response duplication. 2. Prevention of reread. 3. Omission of no tag response. Filtering Filtering function Smoothing Smoothing function V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 41 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 42: Communication Sequence

    Just after the communication transaction, the result is returned promptly. Multi Repeat “MRP” This is used for communicating with multiple tags existing in the read field repeatedly. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 42 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 43 Host→Reader Termination Termination transaction Termination Response* Host←Reader Response Respons Seq1 Seq2 Seq n Seq1 Seq2 ・・・ Reader←→tag (Antenna 1) (Antenna 2) (Antenna n) Existence of tag V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 43 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 44 Timeout Timeout Command Host→Reader Response Response Host←Reader Seq1 Seq2 Seq n Seq1 Seq n ・・・ ・・・ Reader←→Tag Antenna 1) (Antenna 2) (Antenna n) Existence of Tag V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 44 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 45: Session Setting

    (Reference)Function/ effect of each Session flag Flag Tag persistence time after tag energizing is stopped None 500ms to 5s (Same when tag is energized) S2/S3 2s or more 2s or more V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 45 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 46: Communication Data Control

    This function enables the reader to omit the responses if it does not read any tag in the communication sequence (Single Repeat, Multi Repeat) which repeats its transaction. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 46 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 47: Tag Fundamentals

    40-4F EPC[63:48] Area) 50-5F EPC[47:32] 60-6F EPC[31:16] 70-7F EPC[15:0] 00-0F Tag Identification Memory (TID data (read only) 10-1F Area) 00-0F User data (User 10-1F Area) 20-2F V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 47 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 48: Command Interface

    “FCD”. The code is to detect a data error.) The result of the horizontal parity calculation from after SOH through immediately before FCD is expressed by two characters of ASCII code. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 48 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 49 Indicates the results of command execution. Stands for Frame Check Data Terminator [CR,0x0d] Indicates the end of the frame with CR,0x0d. Terminator [LF,0x0a] Indicates the end of the frame with LF,0x0a. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 49 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 50 (Space) 00100000 01001100 01001111 01000011 (Space) 00100000 00101100 01100001 01101110 01110100 (Space) 00100000 00110001 (Space) 00100000 00101100 01110100 01101100 01101111 (Space) 00100000 00110101 00110000 00110000 00011001 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 50 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 51: Command Code Listエラー! ブックマークが定義されていません

    Good Bye Disconnects the Ethernet connection. RRES Request Resend Requests to resend the last response data. TEST Test Tests the communication between host and the R/W. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 51 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 52 (4) Undefined command (in the response frame only) ICMD Illegal Command Command code to be used in the response frame if the R/W receives undefined command. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 52 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 53 * In the case of ID write / Data write, a part of data in the tag may have been written. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 53 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 54: Response Code Listエラー! ブックマークが定義されていません

    Hardware error An error that blocks command execution has been error detected in the hardware (such as malfunction of inner circuit or temporally execution error caused by noise). Response Code の x は、0~9,A-F のいずれかの文字が入ることを示しています。 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 54 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 55: Command / Response Formatエラー! ブックマークが定義されていません

    * Commands are acceptable regardless the character is big or little. Any command works regardless the size combination of characters such as big letters, little letters, or mixed one. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 55 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 56 ID (or data). Data in hexadecimal numbers does not need [0x]. * All hexadecimal numbers as commands and data in the read tags are indicated with capitals (A to F). V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 56 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 57 ・ Min: 0 or 0x00 ・ Max: 32 or 0x20 To write data into a tag with “Write ID” or “Write Data” command, the data Write data V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 57 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 58 STOP command is executed. If the communication sequence is SRP/MRP, the specified value is maximum time between response (0 can’t be specified for SRP/MOC/MRP). ・ 0, 10...2550 (ms) V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 58 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 59 0x00000000. If so, 7Ferror occurs.) Specifies the number(s) that indicates the protocol -ptc 2 -ptc Tag protocol type. Multiple numbers can be specified. ・ 2: Class1 Generation2 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 59 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 60 Reader/Writer may freeze (setting error may occur) depending on the communication performance of the Ethernet or RS-232C. If Ethernet’s traffic is large or the communication speed setting for RS-232C is low, the value shall be set longer. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 60 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 61 [Rx] RDID0000 010 111111111111111111111111 222222222222222222222222 ...(7 Tag IDs)... AAAAAAAAAAAAAAAAAAAAAAAA<LF> Example 5) When an error occurred during communication process: [Tx] RDID -seq SOC -ant 4<LF> [Rx] RDID7000<LF> (The error code [Code:7011] is returned.) V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 61 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 62 [Rx] WTID0000 000<LF> Example 4) When an error has occurred during communication process: [Tx] WTID 1234567890ABCDEF12345678<LF> [Rx] WTID7F00<LF> * The error code is added to the response code. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 62 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 63 (The command data error [Code:1412] is returned.) Example 4) When an error has occurred during communication process: [Tx] RDDT 0 0 1 -ant 123<LF> [Rx] RDDT7000<LF> The error code is returned. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 63 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 64 Example 4) When an error occurred during communication process. [Tx] WTDT 1 32 1234567890ABCDEF12345678 -ant 23 <LF> [Rx] WTDT7011<LF> * The error code [7011] is returned. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 64 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 65 Example 4) When [Password; 0xFFFFFFFF] is specified and specified lock code is incorrect: [Tx] LOCK 2222222222 –pwd FFFFFFFF -ant 2<LF> [Rx] LOCK1411<LF> * The error code [1411] is returned. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 65 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 66 Example 4) When [Password; 0x12] is specified and password has turned out incorrect: [Tx] KILL –pwd 12<LF> [Rx] KILL1421<LF> * The error code [1421] is returned. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 66 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 67 IP address when using static IP address LAN Net Mask xxx.xxx.xxx.xxx 255.255.255.0 Net Mask when using static IP address Default Gateway xxx.xxx.xxx.xxx 192.168/254 IP Address for the Gateway V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 67 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 68 57.6 (kbps) 19.2 38.4 57.6 RS-232C Data length 7 (bit) 7 (bit) RS-232C Parity bit N:none E: even O:odd E:even RS-232C Stop bit 1 (bit) 2 (bit) V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 68 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 69 Example 3) When [RS-232C Baud rate; 19200bps, Data length; 7bit, Parity; Even, and Stop; 1bit] is set: [Tx] SETR rbr=19200 rdt=7 rpb=E rsb=1<LF> [Rx] SETR0000<LF> Example 4) When the setting item is incorrect: [Tx] SETR xxx=111<LF> [Rx] SETR1407<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 69 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 70 Example 3) When [RS-232C Baud rate; 19200bps, Data length; 7 bit, Parity; even, and Stop; 1bit] is read: [Tx] GETR rbr rdt rpb rsb<LF> [Rx] GETR0000 rbr=19200 rdt=7 rpb=E rsb=1<LF> [Tx] GETR rbr rdt rpb rsb<LF> [Rx] GETR0000 rbr=19200 rdt=7 rpb=E rsb=1<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 70 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 71 -Output time is effective only for NML/ ERR setting Evaluation condition * Refer to the following list. Output port #2 function Same as OT1 (None) setting V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 71 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 72 * If there is no condition to be set, any condition shall not be specified. Ex.) When communication error or verify error has been occurred, "dat==7071" V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 72 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 73 2 is XXXX0000 after data read completes normally, output status shall be kept until upcoming evaluation, 出力 3 機能設定を、正常読取り完了時、メモリバンク 1 、アドレス 2 から読 み出したデータが XXXX0000 のときに次回の判定まで出力状態を保持する場合 [Tx] SETO ot3=31 0 1 2 dat=XXXX0000 [Rx] SETO0000<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 73 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 74 [Rx] GETO0000 in1=1 0 "rdid -ant 122322 -tmo 100"<LF> Example 3) When Output 1 function setting is read, [Tx] GETO ot1<LF> [Rx] GETO0000 ot2="31 0 mbk 1 dpt 2 dat=XXXX0000"<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 74 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 75 UHF Power Level (Port3) Same as PW1 31.5 (dBm) UHF Power Level (Port4) Same as PW1 31.5 (dBm) Communication mode 0:Normal mode 0:Normal 1:Dense reader mode mode (DRM) V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 75 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 76 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 76 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 77 Dat; 0x1211] is specified: [Tx] SETC ft1=0 1 20 XX11<LF> [Rx] SETC0000<LF> [Tx] SETC ft2=0 1 20 1211<LF> [Rx] SETC0000<LF> [Tx] SETC fte=1|2 <LF> [Rx] SETC0000<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 77 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 78 Example 2) When [Filter setting, Filter condition 1, Filter condition 2] is read out: [Tx] GETC fte fl1 fl2<LF> [Rx] GETC0000 fte=1&2 ft1=0 1 20 XX11 ft2=0 1 20 1211<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 78 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 79 SAVE 0(<= specified area number ) Response SAVE0000<LF> Example 1) When communication setting is saved (New setting is written into the nonvolatile memory): [Tx] SAVE [Rx] SAVE0000 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 79 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 80 No argument ex. INIT 1(← Initilized range) Response INIT0000<LF> Example 1) All setting of reader is initialized to the factory default setting. [Tx] INIT [Rx] INIT0000 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 80 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 81 [Rx] EXIO0000 1111 1010 Example 2) When [Getting I/O status] is specified: [Tx] EXIO<LF> [Rx] EXIO0000 1011 1001<LF> (From the left side, the following status is shown; IN1...IN4, OUT1…OUT4) V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 81 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 82 Response STOP0000<LF> Example 1) When the Reader/Writer stops multi-repeat communication: [Tx] RDID -seq MRP -ant 12 ---- ReaD ID command starts multi-repeat. [Tx] STOP<LF> [Rx] STOP0000<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 82 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 83 Command GBYE<LF> No argument Response GBYE0000<LF> Example 1) All setting of the reader shall be initialized to factory default setting. [Tx] GBYE<LF> [Rx] REST0000<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 83 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 84 Example 1) When the host requests to resend the response for the External Input Output control command (EXIO) that has been executed most lately. [Tx] RRES<LF> [Rx] EXIO0000 1011 1001<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 84 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 85 *(S) Space Character Example 1) When test data “123456789”is entered to check a communication status between the host and the Reader/Writer: [Tx] TEST 1234567890 [Rx] TEST0000 1234567890 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 85 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 86 *(S) Space Character Example 1) Noise level check for the antenna port 1(US version). [Tx] NOIS 1<LF> [Rx] NOIS0000 1111 2222 3333 4444 ・・・・ nnnn<LF> V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 86 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 87 Tags maintain a corresponding inventoried flag. Sessions allow Tags to keep track of their inventoried status separately for each of four possible time-interleaved inventory processes, using an independent inventoried flag for each process. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 87 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 88: Setting For Communication Conditions エラー! ブックマークが定義されていません。 3.1.5.5 Control Commandエラー! ブックマークが定義されていません。 3.2 Examples

    DECLARE query1 CURSOR FOR SELECT id FROM tag_id WHERE antenna_id=1 AND protocol_id='EPC1' SET time_out=500; SET AUTO query1=ON, repeat=1000; antenna 1 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 88 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 89 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 89 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 90: Example 3

    The effect will be that each reader will have a almost 50% duty cycle with each one only active when the other one is off. Reader 1 Reader 2 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 90 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 91: Example 4

    ID read, Multi Repeat OUT1 Outputs tms when read tag count is 9. OUT2 Communication status output OUT3 Output tms when read tag count is other than 9. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 91 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 92: Example 5

    データ一致時 OUT1 を tms 出力 OUT2 異常終了時に OUT2 を出力 データ読出し(E) 正常終了 N トリガ入力(IN) データ一致(D) 通信処理 通信処理 通信処理 異常出力パルス 一致出力パルス (データ一致) (データ不一致) (データ一致) tms tms 一致出力(OUT1) 異常出力(OUT2) V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 92 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 93: Browser-Based Interface

    4.1 Using the Browser-Based Interface 詳細仕様作成中! 7.1 機能構成 Web ブラウザで接続した後の最初の画面は常に Status 画面となる。各々の画面の最上部と最下部には全ペー ジへのリンクメニューを表示し、1 クリックで任意の画面に移動することができる。Status や Help 画面から他 の画面(オフライン機能)に移動する際には、Ethernet/RS-232C からのコマンドが受け付けられなくなる旨 の Warning Message を出し、OK の場合のみに移行する。オフライン機能は同時に1接続のみで使用可能。 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 93 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 94 オフライン機能 OMRON V750 UHF Reader/Writer Status [Query] [Query] Set Communication Set Operation [Status] Set Reader Utility Update Help OMRON V750 UHF Reader/Writer Status Query [Set Communication] [Set Communication] Set Operation Set Reader [Set Operation] Utility [Set Reader] Update Help OMRON V750 UHF Reader/Writer...
  • Page 95: Web Operation

    :起動時に接続を認識したアンテナ ②[Dynamic Status(動的情報)] 刻々と変化するリーダの状態情報をリアルタイムで表示する。 ・Ethernet 状態 :コマンド I/FPort の Connection Method/Connection 有無 ・実行中のコマンド :起動元、実行コマンド、状態/結果 ・[時刻] :現在時刻 hh:mm:ss [NTP サーバー対応時] ・起動後経過時間 :起動後経過時間 hh:mm:ss Static Status Dynamic Status V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 95 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 96 (2) Query 画面 実際にコマンドを発信し、実行結果を表示することができる。 実行するコマンドの主なオプションは、すべて画面クリックで選択することができ、コマンド体系を熟 知しないユーザでも簡単に操作することができる。また、コマンドラインを編集することを可能にし、熟 達したユーザが自由にコマンドを実行することもできる。 コマンドオプション選択 コマンド編集領域 実行結果表示領域 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 96 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 97 :[機能](機能拡張時に対応)、Host、Domain、DHCP、IP Address、Net Mask、Gateway、 [DNS Server]、[Connection Method]、[Default Host/Port]、[NTP Server]、 [SNMP Server] ・RS-232C 設定 :[機能] (機能拡張時に対応※)、ボーレート、データ構成、[RS/CS 制御有無](機能 拡張時に対応) ※RS-232C 接続の拡張 I/O 対応など、システム I/F 以外に使用する場合 ・[制御ポート] :機能[スキャン接続、アンテナ切替機、など](機能拡張時に対応) 設定反映ボタン 設定項目 設定ファイル指定 リセットボタン V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 97 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 98 (4)Set Operation 画面 リーダの動作条件の情報を表示、設定変更する。 ・コマンド実行後返信先 :登録コマンド実行後の返信先−NON/Ethernet/RS-232C ・電源 ON 動作 :実行コマンド列 ・入力1∼4動作 :機能−なし(ユーザ)/コマンド登録、[起動](機能拡張時に対応※)、実行コマンド 列 ※信号立上り時に以外の起動条件に対応した場合 ・出力1∼4動作 :機能−なし(ユーザ)/状態出力/交信結果判断出力、出力時間、条件 (出力時間と条件は機能を交信結果判断出力時に有効) 設定反映ボタン 設定項目 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 98 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 99 ・Smoothing 機能 :2度読み防止機能、不在レスポンス省略 ・Filtering 機能 :有効/無効、Filtering 条件1−[タグ種類※]/パラメータ(MemBank、Pointer、 Length、Data) ※Gen2 以外のタグの Filtering 機能に対応する場合 ・RF 制御条件 :使用 Session、アンテナ出力レベル、交信実行モード、[LBT 使用]、、[ライト ベリファイ有無] 一斉に設定変更する場合は、所定のフォーマットで項目とその値を記述したファイルをアップロードす ることで、反映させることができる。 各項目の値を記入し、[設定反映ボタン]を押すと、設定が変更される。 [リセットボタン]を押すと、設定値がすべてデフォルト状態に戻される。 設定反映ボタン 設定項目 設定ファイル指定 リセットボタン V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 99 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 100 (6) Utility 画面 リーダを操作する上で、補助となる以下の 2 つの機能を提供する。 ①Channel RF Monitor 各チャネルでの電波の出力状態をモニタリング表示する。 機能切り替え チャネル状態 ②Log Data 表示 起動後に発生したエラーの履歴を最新エラーログと統計エラーログの種類の形式で表示する。リセッ トにより履歴情報はクリアされる。 最新エラーログでは、直前に発生した最大 32 件のエラーを、実行したコマンドコードとエラーコー ド(4桁)で表示する。 統計エラーログでは、各エラーコード(上2桁)毎に発生した回数を表示する。回数の最大は 65535 回である。これ以上に発生した場合にはカウントアップされない。(下記の画面イメージ) 表示データ選択 ログデータ表示 エラー発生回数、発生率 エラーコード V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 100 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 101 (7) Update 画面 ファームウェアのアップグレード時に、ファームウェアファイルを指定して[更新指示]ボタンを押す ことによりファームウェアを更新する。 ファームウェアファイル指定 更新指示 (8) Help 画面 各画面の操作方法、コマンドオプションの意味などを説明する。 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 101 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 102: Safe Mode

    Both of these tasks can be performed via the web interface. 4. Once the maintenance has been performed, restart the reader to activate the changes. Disconnect power from the reader. V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 102 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 103 V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C 103 of 110 OPERATION MANUAL ©OMRON CORPORATION 2006...
  • Page 104: Characteristics(Reference)

    Characteristics data given in this chapter is provided as a guide for the user in determining suitability and does not constitute a warranty. Actual performance may vary based on actual user conditions. 5.1 Communications Range GEN2 Tag Tag is OMRON wave tag. (V750-D22M01) Antenna <Measurement Set-up>...
  • Page 105: Communications Time

    Timeout 値を決定する為のグラフで あるにもかかわらず実フィールドで GEN2 Tags 使用するための値としていない。 Actual Communication Time (ms) Number of Tags:0∼200 DRM ON/OFF Number of Tags V740 RFID READER/WRITER, ANTENNA 2006-06, REV.C 105 of 110 OPERATION MANUAL OMRON CORPORATION 2006...
  • Page 106: Appendix: Outline Drawings

    APPENDIX: OUTLINE DRAWINGS Reader / Writer: (V750-BA50C04-US) Material : Aluminium V740 RFID READER/WRITER, ANTENNA 2006-06, REV.C 106 of 110 OPERATION MANUAL OMRON CORPORATION 2006...
  • Page 107: Antenna : ( V740-Hs01La,V740-Hs01Ca)

    Antenna: (V740-HS01LA, V740-HS01CA) Material: Case PVC, Base plate Aluminum V740 RFID READER/WRITER, ANTENNA 2006-06, REV.C 107 of 110 OPERATION MANUAL OMRON CORPORATION 2006...
  • Page 108: Antenna Cable

    Antenna Cable: (V740-A01-3.0M, V740-A01-10M) Short cable (V740-A01-3.0M) Long cable ( V740-A01-10M) V740 RFID READER/WRITER, ANTENNA 2006-06, REV.C 108 of 110 OPERATION MANUAL OMRON CORPORATION 2006...
  • Page 109 Revision History SRFM – 012 – A Catalog No. Revision Code Revision Code Date Reason for revision/revised page 2006/10 First edition V740 RFID READER/WRITER, ANTENNA 2006-06, REV.C 109 of 110 OPERATION MANUAL OMRON CORPORATION 2006...
  • Page 110 OMRON ELECTRONICS LLC 1920 Thoreau Drive Suite 165 Schaumburg, IL 60173 U.S.A. Tel: (1)847-303-0780/Fax: (1)847-925-1260 Up-to-date information on RFID Systems can be accessed at OMRON's web site at http://www.omronrfid.com/ Printed in Japan Cat. No. SRFM – 012 - A Note: Specifications subject to change without notice.

This manual is also suitable for:

V740-hs01caV740-hs01la

Table of Contents