Appendix A Event Notification Message List
A.2 Message List
Event type
and event
P DASSdd00
P DASSdd00
P DBSSdd00
When the event type is "M"
The following messages are sent when an event that requires maintenance occurs:
Event type
and event
M 13CE0001
M 13CE0002
M 13CE0003
M 13CE0004
M 13CE0005
M 13CE0006
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapItemID
Sensor
code
No.
6
DA00dd00 2
2
DA00dd00 -
2
DB00dd00 -
SNMP Trap
Trap
Trap
Maintenance
code
No.
Info
7
13CE0001
Error session was detected. (Local:xxxxx Remote:xxxxx) These messages
Errors were detected in the copy sessions.
xxxxx: Number of copy sessions in error status
7
13CE0002
Foreseen error session was detected. (Local:xxxxx
Remote:xxxxx)
Errors were detected in the copy sessions during
suspension.
xxxxx: Number of copy sessions in error status during
suspension
7
13CE0003
Halt session was detected. (Remote:xxxxx)
The copy sessions are in halt status.
xxxxx: Number of copy sessions that are halted
7
13CE0004
Error session was cleared.
Errors in the copy sessions were cleared. The copy
sessions are in normal status.
7
13CE0005
Foreseen error session was cleared.
Errors during suspension in the copy sessions were
cleared. The copy sessions are in normal status.
7
13CE0006
Halt session was cleared.
Halt status in the copy session was removed. The copy
sessions are in normal status.
Copyright 2013 FUJITSU LIMITED
Upper: Message
Trap
Lower: Description
Info
DE Exhaust temperature DE#dd Fatal
CE exhaust temperature error or DE exhaust
temperature error (fatal error) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
DE Exhaust temperature sensor DE#dd Fault
CE exhaust temperature error or DE exhaust
temperature error (sensor failure) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
DE Intake temperature sensor DE#dd Fault
CE intake temperature error or DE intake
temperature error (sensor failure) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
Upper: Message
Lower: Description
102
Remarks
These messages
are notified when
"Module was
broken" is enabled
for Error Severity
Level in the event
notification setting.
They are not notified
during maintenance
operations.
Remarks
are notified when
"Copy Session
Error" is enabled for
Error Severity Level
in the event
notification setting.
They are not notified
during maintenance
operations.