Download Print this page

HP 5400 ZL series Quickspecs page 64

5400 zl switch series
Hide thumbs Also See for 5400 ZL series:

Advertisement

QuickSpecs
Accessory Product Details
HP Survivable Branch Communication zl Module powered by Microsoft® Lync (J9485A)
Ports
Physical characteristics
Environment
Notes
Services
HP Services zl Module for Avaya Aura Session Border Controller powered by Acme Packet (J9486A)
Physical characteristics
Environment
Notes
1 USB 2.0
Dimensions
Weight
Operating temperature
Operating relative
humidity
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
Altitude
HP 5400 zl chassis operating temperature specifications when the services module is installed: 45°C when
any services module is installed in the right side of the chassis, 50°C when all services modules are
installed in the left side of the chassis.
Up to four services modules can be installed in an HP 5412 zl/8212 zl Switch chassis simultaneously. Up to
two services modules can be installed in an HP 5406 zl/8206 zl Switch chassis simultaneously.
When the services module is installed, the maximum relative humidity for the switch drops from 95% to
90%.
3-year, 4-hour onsite, 13x5 coverage for hardware (UY932E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UY933E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 SW phone support and SW updates (UY934E)
3-year, 24x7 SW phone support, software updates (UY935E)
3 Yr 6 hr Call-to-Repair Onsite (UY936E)
Refer to the HP website at:
and product numbers. For details about services and response times in your area, please contact your local
HP sales office.
Dimensions
Weight
Operating temperature
Operating relative
humidity
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
Altitude
HP 5400zl chassis operating temperature specifications when the services module is installed: 45°C when
any services module is installed in the right side of the chassis, 50°C when all services modules are
DA - 12436 North America — Version 34 — December 9, 2014
9.75(d) x 8.13(w) x 3.5(h) in. (24.77 x 20.65 x 8.89 cm)
4.5 lb. (2.04 kg)
32°F to 122°F (0°C to 50°C); Important: See note for 50°C temperature spec
rules
15% to 90% @ 104°F (40°C), noncondensing
14°F to 149°F (-10°C to 65°C)
15% to 90% @ 149°F (65°C), noncondensing
up to 10,000 ft. (3 km)
www.hp.com/networking/services
9.75(d) x 8.13(w) x 3.5(h) in. (24.77 x 20.65 x 8.89 cm)
4.5 lb. (2.04 kg)
32°F to 122°F (0°C to 50°C); Important: See note for 50°C temperature spec
rules
15% to 90% @ 104°F (40°C), noncondensing
14°F to 149°F (-10°C to 65°C)
15% to 90% @ 149°F (65°C), noncondensing
up to 10,000 ft. (3 km)
HP 5400 zl Switch Series
for details on the service-level descriptions
Page 64

Advertisement

loading

This manual is also suitable for:

5406-48g zl5412-92g zl5406 zl5412 zl