Download Print this page

HP 5400 ZL series Quickspecs page 40

5400 zl switch series
Hide thumbs Also See for 5400 ZL series:

Advertisement

QuickSpecs
Technical Specifications
Electrical characteristics Frequency
Safety
Emissions
Immunity
Management
Notes
Services
DA - 12436 North America — Version 34 — December 9, 2014
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
Altitude
Acoustic
Description
Maximum heat
dissipation
Voltage
Idle power
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency
magnetic field
Voltage dips and
interruptions
Harmonics
Flicker
HP PCM+; HP PCM (included); command-line interface; Web browser;
configuration menu; out-of-band management (serial RS-232C)
Supported 1G SFP transceivers are revision "B" or later (product number ends
with the letter "B" or later; for example, J9142B, J8177C).
3-year, 4-hour onsite, 13x5 coverage for hardware (UY909E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UY910E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 SW phone support
and SW updates (UY911E)
3-year, 24x7 SW phone support, software updates (UY912E)
Installation with minimum configuration, system-based pricing (U4828E)
Installation with HP-provided configuration, system-based pricing (U4832E)
4-year, 4-hour onsite, 13x5 coverage for hardware (UW452E)
4-year, 4-hour onsite, 24x7 coverage for hardware (UW453E)
HP 5400 zl Switch Series
-40°F to 158°F (-40°C to 70°C)
15% to 95% @ 149°F (65°C), noncondensing
up to 10,000 ft (3 km)
Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO
9296
50/60 Hz
One J9306A installed. One open power supply slot
is available; three different power supplies are
available. See power supply products for
additional specifications.
2450 BTU/hr (2584.75 kJ/hr), (max. non-PoE);
3700 BTU/hr (3903 kJ/hr) (max. using PoE)
110-127/200-240 VAC
215 W
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal
line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30%
reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
Page 40

Advertisement

loading

This manual is also suitable for:

5406-48g zl5412-92g zl5406 zl5412 zl