QuickSpecs
Technical Specifications
Environment
Electrical characteristics Frequency
Safety
Emissions
Immunity
Management
Notes
Services
DA - 12436 North America — Version 34 — December 9, 2014
Operating temperature
Operating relative
humidity
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
Altitude
Acoustic
Description
Maximum heat
dissipation
Voltage
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency
magnetic field
Voltage dips and
interruptions
Harmonics
Flicker
HP PCM+; HP PCM (included); command-line interface; Web browser;
configuration menu; out-of-band management (serial RS-232C)
Supported 1G SFP transceivers are revision "B" or later (product number ends
with the letter "B" or later; for example, J9142B, J8177C).
3-year, 4-hour onsite, 13x5 coverage for hardware (UY914E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UY915E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 SW phone support
and SW updates (UY916E)
3-year, 24x7 SW phone support, software updates (UW440E)
Installation with minimum configuration, system-based pricing (U4828E)
HP 5400 zl Switch Series
32°F to 131°F (0°C to 55°C); 0°C to 40°C with
J8706A or J8707A modules installed
15% to 95% @ 131°F (55°C), noncondensing
-40°F to 158°F (-40°C to 70°C)
15% to 95% @ 149°F (65°C), noncondensing
up to 10,000 ft (3 km)
Power: 64 dB, Pressure: 57.5 dB ISO 7779, ISO
9296
50/60 Hz
Chassis ships without power supplies. Four power
supply slots are available; three different power
supplies are available. See power supply products
for additional specifications.
4900 BTU/hr (5169 kJ/hr), (max. non-PoE); 7400
BTU/hr (7,807 kJ/hr) (max. using PoE)
100-127/200-240 VAC
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal
line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30%
reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3