X9DRD-iF/LF Motherboard User's Manual
Unit Identifier Switch/UID LED Indicators
A Unit Identifier (UID) Switch and two LED Indi-
cators are located on the motherboard. The UID
Switch is located next to the VGA port on the
backplane. The Rear UID LED (LED3) is located
next to the UID Switch. The Front Panel UID
LED is located at pins 7/8 of the Front Control
Panel at JF1. Connect a cable to pin 8 on JF1
for Front Panel UID LED indication. When you
press the UID switch, both Rear UID LED and
Front Panel UID LED Indicators will be turned
on. Press the UID switch again to turn off both
LED Indicators. These UID Indicators provide
easy identification of a system unit that may be
in need of service.
Note: UID can also be triggered via
IPMI on the motherboard. For more
information on IPMI, please refer to the
IPMI User's Guide posted on our web-
site @ http://www.supermicro.com.
2
1
COM2
JUIDB
BMC CTRL
BMC
FAN8
LAN CTRL
JPG1
JPB1
JI2C1
JI2C2
PCH
JBT1
BIOS
C1
D1
CPU1
JPW5
FAN4
JVR1
USB2/3
USB0/1
COM1
VGA
FAN7
LAN2
LAN1
IPMI_LAN
LAN
SP1
CTRL
CLK CTRL
X9DRD-iF
Rev.
1.10
G1
H1
CPU2
B1
A1
JBAT1
JOH1
:OH LED
LED2
2-22
Pin#
1
2
3
4
UID LED (LED3)
Color/State Status
Blue: On
1. UID Switch
2. Rear UID LED (LED3)
3. Front UID LED
USB6
Ground
JPW4
X
FP PWRLED
F1
E1
HDD LED
NIC1 Link LED
3
NIC2 Link LED
Blue+ (OH/Fan Fail/
PWR FaiL/UID LED)
Power Fail LED
Ground
Ground
UID Switch
Definition
Ground
Ground
Button In
Ground
Status
Unit Identified
20
19
NMI
X
3.3 V
ID_UID_SW/3/3V Stby
NIC1 Activity LED
NIC2 Activity LED
Red+ (Blue LED Cathode)
3.3V
Reset
Reset Button
Power Button
PWR
2
1
1