Fan Installation - Casablanca Isotope Owner's Manual

Hide thumbs Also See for Isotope:
Table of Contents

Advertisement

CEILING MOUNTING PLATE INSTALLATION
CEILING HARDWARE (not to scale)
Ceiling Mounting Plate
Note: After removing the old fixture, check the outlet
box to ensure that it is supported by a joist or beam
across its upper surface. If not, a 2 x 4 stud must be
installed.
Step 1a. Carefully feed the ceiling wires through
the center hole of the ceiling mounting plate. Attach
the plate, as shown with ground wire down, to the
ceiling fixture outlet box with the screws provided.
Ensure that the outlet box wires are not pinched by
the washers or between the mounting plate and the
ceiling.
.
CAUTION:
To reduce the risk of personal injury, use
only the mounting hardware provided
with the approved outlet box to install the
crossbar mounting plate.

FAN INSTALLATION

1½" Wood Screws (2) and Washers (2)
1" x 8-32 Roundhead Screws (2) and
Washers (2)
5
I
sotope
Wire Nuts (3)
3" Wood Screws (2)
Washers (2)
JOIST
CEILING
WIRING
CEILING
MOUNTING
PLATE
GREEN
GROUND WIRE
®
Phillips
Screwdriver
CEILING FAN
APPROVED
WIRING BOX
WASHERS
Outlet Box