ZyXEL Communications ES3500-24 User Manual page 295

Es3500 series intelligent l2 switch
Hide thumbs Also See for ES3500-24:
Table of Contents

Advertisement

Table 127 SNMP System Traps (continued)
OPTION
OBJECT LABEL
poe
PwrPortFailedEventOn
PwrPortFailedEventClear
PsePwrFailedEventOn
PsePwrFailedEventClear
temperature
TemperatureEventOn
TemperatureEventClear
voltage
VoltageEventOn
VoltageEventClear
ES3500 Series User's Guide
OBJECT ID
ES3500-24HP:
1.3.6.1.4.1.890.1.5.8.73.27.2.1
ES3500-24HP:
1.3.6.1.4.1.890.1.5.8.73.27.2.2
ES3500-24HP:
1.3.6.1.4.1.890.1.5.8.73.27.2.1
ES3500-24HP:
1.3.6.1.4.1.890.1.5.8.73.27.2.2
ES3500-24:
1.3.6.1.4.1.890.1.5.8.61.27.2.1
ES3500-8PD:
1.3.6.1.4.1.890.1.5.8.72.27.2.1
ES3500-24HP:
1.3.6.1.4.1.890.1.5.8.73.27.2.1
ES3500-24:
1.3.6.1.4.1.890.1.5.8.61.27.2.2
ES3500-8PD:
1.3.6.1.4.1.890.1.5.8.72.27.2.2
ES3500-24HP:
1.3.6.1.4.1.890.1.5.8.73.27.2.2
ES3500-24:
1.3.6.1.4.1.890.1.5.8.61.27.2.1
ES3500-8PD:
1.3.6.1.4.1.890.1.5.8.72.27.2.1
ES3500-24HP:
1.3.6.1.4.1.890.1.5.8.73.27.2.1
ES3500-24:
1.3.6.1.4.1.890.1.5.8.61.27.2.2
ES3500-8PD:
1.3.6.1.4.1.890.1.5.8.72.27.2.2
ES3500-24HP:
1.3.6.1.4.1.890.1.5.8.73.27.2.2
Chapter 39 Access Control
DESCRIPTION
This trap is sent when the port is
turned off to supply power due to
overloading over system budget, or
short circuit.
This trap is sent when the port returns
to the normal state and has the ability
to supply power
This trap is sent when the power
supply of PoE failed. The trigger
situation includes internal/external
power supply failure, external fan
speed failure and external power has
exceed normal temperature.
This trap is sent when the power
supply of PoE returns to the normal
state.
This trap is sent when the temperature
goes above or below the normal
operating range.
This trap is sent when the temperature
returns to the normal operating range.
This trap is sent when the voltage goes
above or below the normal operating
range.
This trap is sent when the voltage
returns to the normal operating range.
295

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es3500-24hpEs3500-8pdEs3500 series

Table of Contents