Operation frequency setting, running and stopping using external
Ex.4
signals.
(1)
Wiring
MCCB
(2)
Parameter setting
Title
(3)
Operation
Run/stop: ON/OFF input to F-CC, R-CC. (Set SW1 to Sink logic)
Frequency setting: VIA and VIB: 0-10Vdc (External potentiometer)
Use the VIA slide switch to switch between voltage and current to the VIA terminal.
Voltage input: V side
Current input: I side
* 600V models have no noise filter inside.
PO
PA/+
PB
PC/-
R/L1
*
S/L2
Noise
Power circuit
T/L3
filter
Braking
circuit
CC
VIA
(Otherwise, input voltage signal (0~10V) between the terminals VIA-CC.)
Function
Command mode selection
Frequency setting mode selection
VIA: Input 4-20mAdc.
C-9
Motor
U/T1
V/T2
IM
W/T3
Run forward signal
F
R
Run backward signal
Common
CC
Current signal: 4∼20mA
VIA
PP
VIB
Voltage signal: 0∼10V
External potentiometer
Programmed value
0
1or2