1. TMS 9250 Torque Measurement System
008-0738-00

SPM Internal Connection

The following table provides detail of internal connection for the SPM. Honeywell does not
recommend that the user change these settings/ connections until/unless assisted by the
factory. Table and pin connection details are listed as follows:
Connector
J1
J4
J5
J6
J7
J13
JP1

Powering of Device

After all the connections are completed, the system should be powered and allowed to warm-
up for 30-45 minutes, in order to get stable outputs from the SPM.

Toolkit Installation

After all the mechanical and electrical setup is completed, software should be installed on the
computer as detailed in the Toolkit Software Manual supplied with the product.
18
© 2012 – Honeywell International Inc. All rights reserved
Function
DC Power 12 V
Current loop output
Voltage output
Frequency output
Primary RS232 port
NOTE: THIS IS THE DEFAULT COMMUNICATIONS PORT
Expansion port
Primary RS232 default select
ATTENTION:
SPM shall be configured for either voltage or current output from
factory hence connectors J4 and J5 are interchangeable but
connector J6 is neither interchangeable with J4 nor J5. Do not
attempt to interchange frequency output to any other output.