Generator Shutdown Procedures - MULTIQUIP WHISPERWATT DCA800SSK2 Operation And Parts Manual

Whisperwatt series 60hz generator (std.) (komatsu saa6d170e-3 diesel engine)
Table of Contents

Advertisement

NORMAL SHUTDOWN PROCEDURE
To shutdown the generator, use the following procedure:
1.
Place the three
auxiliary circuit breakers in the OFF
position (Figure 36)
2.
Place the engine speed switch (Figure 58) in the "LOW"
(down) position.
Figure 58.
Engine Speed Switch (Low)
3.
Let the engine cool by running it at low speed for 3-5
minutes with no load applied.
4.
Place the
MPEC Control Switch (Figure 59) to the
OFF/RESET position.
Figure 59.
MPEC Control Switch (Off/Reset)
5.
Verify that
all the status LEDs on the MPEC display
are OFF (not lit).
6.
Set the
battery ON/OFF switch (Figure 60) to the
"OFF" position.
Figure 60.
Battery Switch (OFF)
7.
Remove all loads from the generator.
8.
Inspect entire generator for any damage or loosening
of components that may have occurred during
operation.
DCA800SSK2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (09/03/09) — PAGE 37

GENERATOR SHUTDOWN PROCEDURES

EMERGENCY SHUTDOWN PROCEDURE
1.
To stop the engine in the event of an emergency,
the emergency stop button (Figure 61) inward. This
button is located on the engine operating panel, see
Figure 5.
Figure 61.
Emergency Stop Button
PUSH