Summary of Contents for MULTIQUIP Whisperwatt Dca70Usi3caN
Page 1
OperatiOn and parts Manual ® WhisperWatt™ series MODeL Dca70Usi3caN 60hz geNeratOr (isUzU BJ4JJ1-XYgD-02 DieseL eNgiNe) parts List NO. M2870400304c M2874400004 Revision #1 (09/24/13) To find the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
FUeL aND cheMicaL WarNiNg Diesel engine exhaust and some of its constituents are know to cause cancer, birth defects and other reproductive harm. page 2 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
1-888-327-4236 (TTY: 1-800-424-9153), go to http://www.nhtsa.dot.gov; or write to: Administrator NHTSA 1200 New Jersey Avenue S.E. Washington, DC 20590 You can also obtain information about motor vehicle safety from http://www.safecar.gov. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 3...
All orders are treated as Standard Orders and will ship the same day if received prior to 3PM PST. WE ACCEPT ALL MAJOR CREDIT CARDS! DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 5...
CAUTION Indicates a hazardous situation which, if not avoided, CoUlD result in mInor or moDerate InJUrY. NOTICE Addresses practices not related to personal injury. page 6 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
alWaYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 7...
Page 8
never touch the hot exhaust manifold, local Health and Safety Administrator. muffl er or cylinder. Allow these parts to cool before servicing equipment. page 8 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
Use the trailer’s swivel jack to adjust the trailer height to alWaYS shutdown engine before transporting a level position while parked. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 9...
alWaYS recharge the battery in a well-ventilated possibility exists of electrical shock, environment to avoid the risk of a dangerous concentration electrocution or death. of combustible gasses. page 10 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
Recyclers and manufacturers alike promote the process of recycling metal. Using a metal recycling center promotes energy cost savings. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 11...
30.20 in. (766 mm.) 68.30 in. (1,735 mm.) 30.20 in. (766 mm.) 37.40 in. (950 mm.) 30.20 in. (766 mm.) 30.20 in. (766 mm.) DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 13...
They are to resist damage to the bottom of the generator and to maintain alignment. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 15...
Five output terminal lugs (3Ø power) a minimum. Use the cable selection chart (Table 6) as a guide for selecting proper extension cable size. page 16 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
7. Frequency meter — Indicates the output frequency main circuit breaker in the closed position (ON). in hertz (Hz). Normally 60 Hz. page 18 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
Page 19
NOtes DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 19...
ECU will attempt to F. Engine Running — Indicates that engine is running crank the engine for 10 seconds at a safe operating speed. before disengaging. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 21...
175A main circuit breaker is provided. Make sure to switch all circuit breakers to the OFF position prior to starting the engine. Figure 12. Over Current Relay Figure 11. Connecting Loads page 24 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
1800 3600 150 ft. 100 ft. 65 ft. 2400 4800 125 ft. 75 ft. 50 ft. CAUTION: Equipment damage can result from low voltage DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 25...
W and U terminals as indicated on the AC Voltmeter Gauge (Figure 16) Figure 15. aC voltmeter Figure 16. aC voltmeter Change-Over Switch Gauge DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 27...
To achieve a 3Ø 208V output the voltage selector switch Figure 20. UVWO Terminal Lugs must be in the 3Ø-240/139 position and the voltage 3Ø-240/139V Connections regulator must be adjusted to 208V.. page 28 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
Page 29
UVWO terminals are secure and tight. The possibility of arcing exists, that could cause a fire. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 29...
API Service Classification CC/SD API Service Classification CC/SE API Service Classification CC/SF table 11. recommended motor oil Figure 29. Internal Fuel Tank System page 30 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
Page 31
#2 diesel fuel when refueling. Do not overFIll fuel system. Leave room for fuel expansion. Fuel expands when heated (Figure 33). Figure 33. Fuel Expansion DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 31...
Boiling Point Anti- °C °F °C °F Freeze NOTICE When the antifreeze is mixed with water, the antifreeze mixing ratio must be less than 50%. page 32 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
Tighten all hose clamps and check hoses for leaks. Figure 35. Battery Connections If any hose (fuel or oil) lines are defective replace them immediately. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 33...
4. Once the engine starts, let the engine run for 1-2 minutes. Listen for any abnormal noises. If any abnormalities exist, shut down the engine and correct page 34 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
(Figure 46) to approximately 1800 RPM’s. increase or decrease the desired voltage. Figure 46. Voltage Adjust Control Knob Figure 50. Engine Tachometer Gauge DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 35...
When ready to restart, complete all steps in the Generator Startup Procedure Figure 53. Main, GFCI and Load section of this manual. Circuit Breakers (OFF page 36 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 37...
Page 38
To restart after running out of fuel, turn the switch to the “ON” position for 15-30 seconds. Try again, if needed. Figure 57. Fuel Tank Cleaning page 38 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
Allow engine to cool when flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 39...
16. Application — Indicates which units can be employed on a particular trailer. 7. Coupler — Type of hitch used on the trailer for towing. page 40 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
“ON” position, the engine will not be stopped even if the starter switch is turned to the “OFF” position. In such case, turn the diagnostic switch to the “OFF” position. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 49...
Multiquip. Other entries will for sale through Multiquip. be clarified in the “Remarks” Column. page 50 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
2....0601810245 ..BULB, ALARM LAMP NOTICE Part number on this Suggested Spare Parts list may supersede/replace the P/N shown in the text pages of this book. DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 51...
NUMBER WHEN ORDERING ANY PAINTED PANEL TO INDICATE COLOR OF UNIT: 1-ORANGE 5-BLACK 2-WHITE 6-CATERPILLAR YELLOW 3-SPECTRUM GREY 7-CATO GOLD 4-SUNBELT GREEN 8-RED THE SERIAL NUMBER MAY BE REQUIRED. page 64 — DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13)
0228800790 SEAL RUBBER 0228800475 SEAL RUBBER 0228100325 SEAL RUBBER 0228100420 SEAL RUBBER 0228900700 SEAL RUBBER 0228900640 SEAL RUBBER 0229200295 SEAL RUBBER 0229200220 SEAL RUBBER DCa70USI3Can 60 hz generator • operatIon anD partS manUal — rev. #1 (09/24/13) — page 79...