Mode 2 Bidirectional Timing; Figure 4-40. Mode 2 Bidirectional Timing - National Instruments AT-MIO/AI E Series User Manual

Multifunction i/o boards for the pc at
Table of Contents

Advertisement

WR *
OBF *
INTR
ACK *
STB *
IBF
RD *
DATA
National Instruments Corporation

Mode 2 Bidirectional Timing

The following are the timing specifications for bidirectional transfers in
Mode 2:
T1
T3
T4
T2

Figure 4-40. Mode 2 Bidirectional Timing

Name
Description
T1
WR* = 1 to OBF* = 0
T2
Data before STB* = 1
T3
STB* Pulse Width
T4
STB* = 0 to IBF = 1
T5
Data after STB* = 1
T6
ACK* = 0 to OBF = 1
T7
ACK* Pulse Width
T8
ACK* = 0 to Output
T9
ACK* = 1 to Output Float
T10
RD* = 1 to IBF = 0
All timing values are in nanoseconds.
T6
T7
T5
T8
4-57
Chapter 4
Signal Connections
T9
Minimum
Maximum
150
20
100
150
50
150
100
150
20
250
150
AT-MIO/AI E Series User Manual
T10