Figure 3-9. Below-Low-Level Analog Triggering Mode; Figure 3-10. Above-High-Level Analog Triggering Mode; Figure 3-11. Inside-Region Analog Triggering Mode - National Instruments AT-MIO/AI E Series User Manual

Multifunction i/o boards for the pc at
Table of Contents

Advertisement

National Instruments Corporation
lowValue
Trigger

Figure 3-9. Below-Low-Level Analog Triggering Mode

In above-high-level analog triggering mode, the trigger is
generated when the signal value is greater than highValue.
LowValue is unused.
highValue
Trigger

Figure 3-10. Above-High-Level Analog Triggering Mode

In inside-region analog triggering mode, the trigger is generated
when the signal value is between the lowValue and the highValue.
highValue
lowValue
Trigger

Figure 3-11. Inside-Region Analog Triggering Mode