Mode 1 Input Timing; Figure 4-38. Mode 1 Input Timing - National Instruments AT-MIO/AI E Series User Manual

Multifunction i/o boards for the pc at
Table of Contents

Advertisement

National Instruments Corporation

Mode 1 Input Timing

The following are the timing specifications for an input transfer in
Mode 1:
STB *
IBF
INTR
RD *
DATA
Name
Description
T1
STB* Pulse Width
T2
STB* = 0 to IBF = 1
T3
Data before STB* = 1
T4
STB* = 1 to INTR = 1
T5
Data after STB* = 1
T6
RD* = 0 to INTR = 0
T7
RD* = 1 to IBF = 0
All timing values are in nanoseconds.
T1
T2
T4
T3
T5

Figure 4-38. Mode 1 Input Timing

4-55
Chapter 4
Signal Connections
T7
T6
Minimum
Maximum
100
150
20
150
50
200
150
AT-MIO/AI E Series User Manual