How To Use The Terminals Of The Alarm Connector - Panasonic WJ-HD309 Operating Instructions Manual

Digital disk recorders
Hide thumbs Also See for WJ-HD309:
Table of Contents

Advertisement

■ How to Use the Terminals of the ALARM Connector

These terminals are used to connect the alarm devices, such as sensors, door switches, etc.
The pin configurations of these terminals are as shown below. The connector used should be compatible with the pin configu-
ration.
Pin Configuration
The pin array is different from other disk recorders. Make sure that the connection is correct referring to the following.
Pin No.
q
Ch 1 alarm input
w
Ch 2 alarm input
e
Ch 3 alarm input
r
Ch 4 alarm input
t
Ch 5 alarm input
y
Ch 6 alarm input
u
Ch 7 alarm input
i
Ch 8 alarm input
o
Ch 1 alarm output
!0
Ch 2 alarm output
!1
Ch 3 alarm output
!2
Ch 4 alarm output
!3 , !4
Earth (Grounding)
!5
Ch 9 alarm input
!6
Ch 10 alarm input
!7
Ch 11 alarm input
!8
Ch 12 alarm input
!9
Ch 13 alarm input
@0
Ch 14 alarm input
@1
Ch 15 alarm input
@2
Ch 16 alarm input
@3
Ch 5 alarm output
@4
Ch 6 alarm output
@5
Ch 7 alarm output
86
!3
@5
Pin No.
Event action will be performed according
to the settings.
Alarm signal will be supplied at an event
occurrence
Event action will be performed according
to the setting.
Alarm signal will be supplied at an event
occurrence
q
ALARM
!4
Operation
Remarks
Non-voltage make contact/–100 mA,
5 V pull-up
Open collector output/24 V, 100 mA
Non-voltage make contact input/
–100 mA, 5 V pull-up
Open collector output/24 V max.,
100 mA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wj-hd316

Table of Contents