Default
A VFC interface is up.
Views
VFC interface view
Predefined user roles
network-admin
Examples
# Bring up interface VFC 1.
<Sysname> system-view
[Sysname] interface vfc 1
[Sysname-Vfc1] undo shutdown
Fabric setup commands
allowed-domain-id
Use allowed-domain-id to specify the allowed domain ID list for a specific VSAN on the switch.
Use undo allowed-domain-id to restore the default.
Syntax
allowed-domain-id domain-id-list
undo allowed-domain-id domain-id-list
Default
The default setting is 1 to 239.
Views
VSAN view
Predefined user roles
network-admin
Parameters
domain-id-list: Specifies a list of allowed domain IDs, in the format of domain-id-list = { domain-id1 [ to
domain-id2 ] }&<1-8>, where domain-id1 and domain-id2 specify domain IDs in the range of 1 to 239
and domain-id2 must be no smaller than domain-id1. &<1-8> indicates that you can specify up to eight
domain-id1 [ to domain-id2 ] parameters.
Usage guidelines
Each FCF switch is assigned a domain ID. You can specify the allowed domain ID list.
Configuring the allowed domain ID list has an effect on switches as follows:
Principal switch—Can only assign domains IDs within the allowed domain ID list. If the allowed
•
domain ID list configured does not include any of the already assigned domain IDs or manually
configured domain IDs, the configuration will fail.
•
Non-principal switch—The manually configured domain ID must be within the allowed domain ID
list. Otherwise, the configuration will fail. The principal switch must assign the switch a domain ID
14