Vertical Scan Switch
One vertical switch is used for the three CRT's. See position of the switch (diagrams) for the corresponding projector configuration.
To set the vertical scan switch :
•
Remove the vertical deflection module (the third module viewing from the rear of the projector).
To remove the vertical deflection module :
- Press the module lock and lift up the module handle;
- Repeat this action on both sides of the module and extract the module out of the main frame.
•
Toggle the vertical scan inversion switch to the correct position.
•
Reinstall the vertical deflection module.
Positioning the scan switches for the different mounting configurations
Positions of the scan switches for the different mounting configurations are illustrated below.
3-6
Vertical scan switch
Connectors for the vertical
deflection module
Vertical deflection module
5976065 BARCOCINE 8 08022000