Pre-Alarm Recording; Alarm Trigger - Sanyo DSR-3016P Manual For Remote Operation

Manual for remote operation by network connection
Hide thumbs Also See for DSR-3016P:
Table of Contents

Advertisement

Menu Setting Procedures

PRE-ALARM RECORDING

This specifies whether pre-alarm recording will be
carried out or not, and sets the recording conditions
when pre-alarm recording is carried out. (See p. 22)
1
Select "ON/OFF" from the [PRE-ALARM
RECORDING] menu.
• ON:
Pre-alarm recording is carried out.
• OFF: Pre-alarm recording is not carried out.
When [ALARM RECORDING] is set to "OFF", "**"
is displayed and pre-alarm setting cannot be
carried out.
2
Select the recording cycle from the [REC RATE]
menu.
A 50, A 25, A 16.7, A 12.5, A 8.33, 6.25, 5, 4.17, 3.57, 3.13,
2.78, 2.50, 2.27, 1.92, 1.67, 1.47, 1.32, 1.19, 1.09, 1 (Units:
FPS)
(Default setting: A 12.5 FPS)
A 50 FPS can only be selected when the NORMAL
REC AREA capacity setting is 0%.
3
Select the pre-alarm recording duration from the
[DURATION] menu.
2 SEC, 3 SEC, 5 SEC, 10 SEC, 20 SEC, 40 SEC, 1 MIN,
2 MIN, 3 MIN, 4 MIN, 5 MIN, 10 MIN, 15 MIN
(Default setting: 1 MIN)

ALARM TRIGGER

This sets an alarm trigger (a signal for alarm
recording to begin) that will become the condition for
the operation of alarm recording.
1
Select an alarm recording starting signal from
the menu.
• ALARM:
Alarm recording starts when an external
alarm reacts.
• SENSOR: Alarm recording starts when a motion
sensor reacts.
• ALARM AND SENSOR:
Alarm recording starts when an external
alarm and motion sensor both react at the
same time.
• ALARM OR SENSOR:
Alarm recording starts when either an
external alarm or a motion sensor react.
External alarm detection: This is when external sensor information (such as the opening or closing of a door switch)
is input to the digital video recorder's alarm input terminals while the digital video recorder is online.
Motion sensor detection: This is when the motion sensor settings cause movement to be detected on the monitor
screen.
Click [SAVE] to complete the settings (or changes) for the sub-menu that is displayed on the screen. The
number of alarm recordings available under the conditions that have been set will be displayed in
parentheses for reference.
English
(Default setting: ALARM)
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsr-3009p

Table of Contents