Passcode Follows Scope; Description; Using Passcode Follows Scope - Bosch GV2 Series Owner's Manual

Supplement
Hide thumbs Also See for GV2 Series:
Table of Contents

Advertisement

GV2 Series Control Panels | Owner's Manual Supplement
2.4

Passcode Follows Scope

2.4.1

Description

The Passcode Follows Scope feature is an optional arming and
disarming restriction that can be enabled on keypads with access
to multiple areas. When this feature is set to No, the keypad
restricts Passcode Arming and Passcode Disarming to the home
area of the keypad. When set to Yes, this feature allows users to
arm or disarm all the areas to which they and the keypad have
access. This feature causes no restrictions to the keypad scope as
it pertains to any command or arming method other than
Passcode Arming or Passcode Disarming.
2.4.2

Using Passcode Follows Scope

Arming from a keypad with Panel Wide scope and Passcode
Follows Scope enabled:
1. Ensure that the keypad shows idle disarmed text.
2. Ensure that you have a valid passcode with the authority to
Passcode Arm in all areas.
3. Enter your passcode by pressing the [passcode digits]
followed by the [ENTER] key (D1260) or [ENT] key (D1255).
4. The keypad shows ARMING: 12345678 to indicate which areas
are ready to enter exit delay and arm.
5. The keypad shows the exit delay countdown.
6. Exit from the premises.
Arming from a keypad with Panel Wide scope and Passcode
Follows Scope disabled (default):
1. Ensure that the keypad shows idle disarmed text.
2. Ensure that you have a valid passcode with the authority to
Passcode Arm in all areas.
3. Enter your passcode by pressing the [passcode digits]
followed by the [ENTER] key (D1260) or [ENT] key (D1255).
4. The keypad shows the exit delay countdown.
5. Exit from the premises.
8
I have this feature.
I do not have this feature.
Bosch Security Systems, Inc. | 2/07 | F01U063791-01

Advertisement

Table of Contents
loading

Table of Contents