Alarms Acknowledged Within The Abort Window; At The End Of The Alarm Abort Window; Cancel Report And Cancel Window; Duress Alarm - Bosch GV2 Series Owner's Manual

Supplement
Hide thumbs Also See for GV2 Series:
Table of Contents

Advertisement

GV2 Series Control Panels | Owner's Manual Supplement
3.6.3

Alarms Acknowledged within the Abort Window

If the end user acknowledges an alarm within the Abort Window:
The alarm output is silenced.
No alarm, restoral, or cancel reports are sent.
No alarm, restoral, or cancel reports are entered in the control
panel event log.
3.6.4

At the End of the Alarm Abort Window

If no user acknowledges the alarm within the Alarm Abort Window,
the control panel sends the appropriate alarm reports.
3.7

Cancel Report and Cancel Window

If a user acknowledges an alarm after the Abort Window expires,
but before Bell Time expires, the control panel sends a Cancel
Report. The Cancel Window starts when the alarm is sent and
stops when the Alarm Bell timer expires or a user acknowledges
an alarm.
3.8

Duress Alarm

This feature allows any passcode with the Send Duress permission
enabled to always send a Duress Alarm event upon entry. The
Duress Alarm feature allows an installation to allocate unique
passcodes as the main duress passcodes for all users.
Additionally, when the SIA CP-01 compliant Duress Alarm option is
enabled, the Passcode +1 and +2 options are disabled.