Global View Station 1000
6.3

Auxiliary Controls

6.3.1

Aux 1 2x Doubler Function

6.3.2

Aux 2 Wiper Function

6.3.3

Aux 3 Illuminator Control

6.3.4

Aux 4 Iris Control

6.3.5

Aux 5 Lens IR Correction Mode

6.3.6

Aux 6 Camera Color/Mono Mode

6.3.7

Aux 7 ZX700 IR On/Off Control

6.3.8

Aux 8 SLED IR On/Off Control

Bosch Security Systems, Inc.
LED1 – doubler function indicator
LED1 ON = doubler on
LED1 OFF = doubler off
Default: OFF
LED2 – wiper function indicator
LED2 ON = wiper on
LED2 OFF = wiper off
Default: OFF
LED3 – illuminator control indicator
LED3 ON = automatic photocell control on
LED3 OFF = manual control on (photocell off)
Default: MANUAL control mode (LED off)
No Aux4 indicator present on this board, only on Camera Control board
LED5 – IR correction mode indicator
LED5 ON = lens IR-correction enabled
LED5 OFF = lens IR-correction disabled
Default: IR-correction disabled
LED6 – camera mode indicator
LED6 ON = monochrome mode on
LED6 OFF = color mode on
Default: color mode
LED7 – ZX700 on/off indicator
LED7 ON = ZX700 on
LED7 OFF = ZX700 off
Default: ZX700 off
CN3 – relay connection to Meanwell PSU for control
LED8 – SLED on/off indicator
LED8 ON = SLED on
LED8 OFF = SLED off
Default: SLED off
LED11 – indicates power input to SLED control boards
Default: LED11 on (showing power available for SLED)
CN4 – relay connection to two SLED control boards
T3 – power input to current control board