Bosch GVS1000 Operation Manual page 8

Global view station 1000
Hide thumbs Also See for GVS1000:
Table of Contents

Advertisement

8
en | Safety
Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid
electrostatic discharge.
NOTE: Wear required grounded wrist straps and observe proper ESD safety precautions when
handling the electrostatic-sensitive printed circuit boards.
Fuse rating - For security protection of the device, the branch circuit protection must be
secured with a maximum fuse rating of 16A. This must be in accordance with NEC800 (CEC
Section 60).
Grounding and polarization - This unit may be equipped with a polarized alternating current
line plug (a plug with one blade wider than the other blade). This safety feature allows the
plug to fit into the power outlet in only one way. If unable to insert the plug fully into the
outlet, contact a locally certified electrician to replace the obsolete outlet. Do not defeat the
safety purpose of the polarized plug.
Alternately, this unit may be equipped with a 3-pole grounding plug (a plug with a third pin for
earth grounding). This safety feature allows the plug to fit into a grounded power outlet only.
If unable to insert the plug into the outlet, contact a locally certified electrician to replace the
obsolete outlet. Do not defeat the safety purpose of the grounding plug.
Moving - Disconnect the power before moving the unit. Move the unit with care. Excessive
force or shock may damage the unit and the hard disk drives.
Outdoor signals - The installation for outdoor signals, especially regarding clearance from
power and lightning conductors and transient protection, must be in accordance with NEC725
and NEC800 (CEC Rule 16-224 and CEC Section 60).
Permanently connected equipment - Incorporate a readily accessible disconnect device in
the building installation wiring.
Pluggable equipment - Install the socket outlet near the equipment so it is easily accessible.
Power resupply - If the unit is forced to power down due to exceeding the specified operating
temperatures, disconnect the power cord, wait for at least 30 seconds, and then reconnect
the power cord.
Power lines - Do not locate the camera near overhead power lines, power circuits, or
electrical lights, nor where it may contact such power lines, circuits, or lights.
Rack-mount
SELV
All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should
only be connected to other SELV circuits.
Because the ISDN circuits are treated like telephone-network voltage, avoid connecting the
SELV circuit to the Telephone Network Voltage (TNV) circuits.
The system ground is only used to comply with safety standards or installation practices in
certain countries. Bosch does not recommend connecting system ground to safety ground
unless it is explicitly required. However, if the system ground and safety ground are
connected and grounding loops are causing interference in the video signal, use an isolation
transformer (available separately from Bosch).
CAUTION!
Connecting System ground to Safety ground may result in ground loops that can disrupt the
CCTV system.
F.01U.173.867 | 2.0 | 2010.11
Ventilation - Do not place this unit in a built-in installation or rack without proper
ventilation or adhering to the manufacturer's instructions. The equipment must not
exceed its maximum operating temperature requirements.
Mechanical loading - Properly mount the equipment in a rack to prevent a hazardous
condition due to uneven mechanical loading.
Operations Manual
Global View Station 1000
Bosch Security Systems, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Global view station 1000

Table of Contents