Installation Preparations Mounting Connections Power on/power off Adjusting the lens (only WFOV lenses) Final assembly Setup using Bosch Video Client Configuration using a Web browser Connecting Configuration menu Basic Mode: Device Access Basic Mode: Date/Time Basic Mode: Network Basic Mode: Encoder...
Page 4
Operation using software decoders Maintenance and upgrades Testing the network connection Camera reset Fuse replacement Repairs Transfer and disposal Export limitations Appendix Troubleshooting General malfunctions Malfunctions with iSCSI connections DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 5
VOT-320 Table of Contents | en LEDs Processor load Network connection Serial interface Terminal blocks Communication with terminal program 8.10 Copyrights Specifications Camera Detector Protocols/standards Glossary Index Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Intended use The thermal IP camera VOT-320 transfers video and control signals over data networks (Ethernet LAN, Internet). There are various memory options for recording the captured images. The camea is intended for use with CCTV systems. Various functions can be triggered automatically by incorporating external alarm sensors.
VOT-320 Preface | en EU Directives The thermal IP camera VOT-320 complies with the requirements of EU Directives 89/336 (Electromagnetic Compatibility) and 73/23, amended by 93/68 (Low Voltage Directive). Rating plate For exact identification, the model name and serial number are inscribed on the back of the housing.
– If safe operation of the camera cannot be ensured, remove it from service and secure it to prevent unauthorized operation. In such cases, have the unit checked by Bosch Security Systems. Safe operation is no longer possible in the following cases: –...
(electrical engineers or network technology specialists). CAUTION! If the camera is mounted to a pan/tilt, ensure that your hands do not get caught or crushed between camera and pan/tilt. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Adobe Acrobat Reader NOTICE! Check that the delivery is complete and in perfect condition. Arrange for the unit to be checked by Bosch Security Systems if you find any damage. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
– Microsoft Internet Explorer (version 7.0 or higher) – Receiver software, for example Bosch Video Client (version 1.0 or higher) or Bosch Video Management System (version 2.3 or higher) – H.264 compatible hardware decoder from Bosch Security Systems (for example VIP XD) as a receiver and connected video monitor –...
Neither dense smoke nor bad weather conditions as heavy fog or snow affect visibility. With a VOT-320 there is no need for natural or artificial lighting of the area of interest.
Page 13
Tamper detection and video content analysis The VOT-320 offers a wide range of configuration options for alarm signaling in the event of tampering with the camera. Two algorithms for detecting movement in the video image, MOTION+ and IVA are integrated offering extended video content analysis.
Page 14
| Product description VOT-320 Summary The thermal IP camera VOT-320 provides the following main functions: – Outstanding image quality with 320 × 240 VOx sensor – Video and data transmission over IP data networks – Tri-streaming function for the encoder for simultaneous encoding with three individually definable profiles –...
Opening D: LED group D information on camera and pan/tilt functions Opening E: fuse holder F501 NOTICE! For more information about the LEDs, see Section 8.4 LEDs, page 97. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
CAUTION! If the camera is mounted to a pan/tilt, ensure that your hands do not get caught or crushed between camera and pan/tilt. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Page 18
Sealants that release acetic acid may harm camera electronics. Use of drip loops is recommended on the wiring outside of the rear end cap. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
VOT-320 Installation | en Connections Network You can connect the VOT-320 to a 10/100 Base-T network using a standard UTP category 5 cable with RJ45 plugs. EIA/TIA-568-A EIA/TIA-568-B white/green white/orange green orange white/orange white/green blue blue white/blue white/blue orange green...
Page 20
Alarm inputs The VOT-320 has two alarm inputs on the lower 6-pin terminal block (see Section 8.8 Terminal blocks, page 99). The alarm inputs are used to connect to external alarm devices such as door contacts or sensors. With the appropriate configuration, an alarm sensor can automatically connect the VOT-320 to a remote location, for example.
The VOT-320 does not have a power switch. Power is supplied via a separate unit. Connect the VOT-320 to the power supply unit and plug this into the mains. The camera is now ready for use. The VOT-320 does not come supplied with a power supply unit.
NOTICE! Using Bosch Video Client to set all parameters in the VOT-320 is an alternative to configuration by means of a Web browser, as described in chapter 5 of this manual.
Page 23
Follow the instructions given in the Configuration Wizard window. Additional parameters You can check and set additional parameters with the assistance of the Configuration Manager application in Bosch Video Client. You can find detailed information on this in the documentation for these applications. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Configuration using a Web browser Connecting The integrated HTTP server in the VOT-320 provides you with the option to configure the camera over the network with a Web browser. This option is an alternative to configuration using the Configuration Manager application in Bosch Video Client and is considerably richer in function and more convenient than configuration using the terminal program.
Page 25
Configuration using a Web browser | en Establishing the connection Before you can operate the VOT-320 within your network, it must have a valid IP address for your network and a compatible subnet mask. The following default address is preset at the factory: 192.168.0.1 Start the Web browser.
The settings in the Advanced Mode should only be processed or modified by expert users or system support personnel. All settings are backed up in the VOT-320 memory so they are not lost even if the power fails. The exception is the time settings, which are lost after 72 hours without power if no central time server is selected (see Section 5.4 Basic Mode: Date/Time, page 29).
Page 27
CAUTION! Save each change with the associated Set button. Clicking the Set button saves the settings only in the current field. Changes in any other fields are ignored. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Special characters are not supported by the system's internal management. Password A VOT-320 is generally protected by a password to prevent unauthorized access to the camera. You can use different authorization levels to limit access. The VOT-320 operates with three authorization levels: service, user and live.
Click the Sync to PC button to copy your computer's system time to the VOT-320. Time server IP address The VOT-320 can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock.
IP address is assigned, it is retained each time the system is rebooted. IP address Enter the desired IP address for the VOT-320 in this field. The IP address must be valid for the network. Subnet mask Enter the appropriate subnet mask for the selected IP address here.
For ISDN connections via two B-channels – ISDN (1B) For ISDN connections via one B-channel – MODEM For analog modem connections with 20 kbps – For GSM connections at 9,600 baud Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Camera 1 parameters. The window will close. Initiator extension You can attach your own text to the initiator name of the VOT-320 to make the camera easier to identify in large iSCSI systems. This text is added to the initiator name, separated from it by a full stop.
VOT-320 5.10 Advanced Mode: Password A VOT-320 is generally protected by a password to prevent unauthorized access to the camera. You can use different authorization levels to limit access. NOTICE! Proper password protection is only guaranteed when all higher authorization levels are also protected with a password.
– it is added automatically. Enter the current time or click the Sync to PC button to copy your computer's system time to the VOT-320. Device time zone Select the time zone in which your system is located.
Now click the OK button to apply and activate the table. Time server IP address The VOT-320 can receive the time signal from a time server using various time server protocols, and then use it to set the internal clock. The camera polls the time signal automatically once every minute.
Internet/Intranet). When accessing via the Internet/Intranet, ensure that a connection is always available to display the image. The image file is not stored in the VOT-320. Website language Select the language for the user interface here.
Show relay outputs Relay outputs are shown next to the video image as icons, along with their assigned names. If the relay is switched, the icon changes color. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Enter the path for saving the event log here. If necessary, click Browse to find a suitable directory. Save system log Check this option to save system messages in a text file on your local computer. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
You can change the names and individual parameter values for the encoder profiles. You can use this to adapt the video data transmission to the operating environment (for example network structure, bandwidth, data load). DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 41
Special characters are not supported by the system's internal management. Target bit rate You can limit the bit rate for the VOT-320 to optimize utilization of the bandwidth in your network. The target bit rate should be set according to the desired picture quality for typical scenes with no excessive motion.
Page 42
With the slide control, define a control range from a chosen value to 51. The encoder delivers the best possible quality within this control range while maintaining the maximum bit rate. Default Click Default to return the profile to the factory default values. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
5.18 Advanced Mode: Encoder Streams The VOT-320 simultaneously generates two H.264 data streams (Dual Streaming); you can select the relevant property for these here and connect them to an encoder profile, for example one for transmissions to the Internet and one for LAN connections.
Page 44
You can select the maximum frame rate for transmitting the JPEG images. Picture quality This setting allows you to define the picture quality. Low quality requires a lower bandwidth in the network. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
It is also possible to let the VRM Video Recording Manager control all recording when accessing an iSCSI system. This is an external program for configuring recording tasks for videos. For further information please contact your local customer service at Bosch Security Systems.
Page 46
Each storage medium can only be associated with one user. If a storage medium is already being used by another user, you can decouple the user and connect the drive with the VOT-320. Before decoupling, make absolutely sure that the previous user no longer needs the storage medium.
Page 47
Click a storage medium in the Managed storage media list to select it. Click the Remove button below the list. The storage medium is deactivated and removed from the list. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
(see Section 5.18 Advanced Mode: Encoder Streams, page 43). The properties of the profiles are defined on the Encoder Profile page (see Section 5.17 Advanced Mode: Encoder Profile, page 40). DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 49
You can select an alternative encoding interval for the data stream for alarm recordings. Otherwise the encoding interval of the selected encoder profile is used (see Section 5.17 Advanced Mode: Encoder Profile, page 40). Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Section 5.31 Advanced Mode: Alarm Inputs, page 66). The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the alarm inputs on the VOT-320. The motion alarm is configured and activated on the VCA page (see Section 5.25 Advanced Mode: VCA, page 56 onwards).
Click the Select All button to link all time intervals to the selected profile. Click the Clear All button to deselect all of the intervals. When you are finished, click the Set button to save the settings in the camera. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Page 52
Click Start to activate the recording scheduler. Click Stop to deactivate the recording scheduler. Running recordings are interrupted. Recording status The graphic indicates the recording activity of the VOT-320. You will see an animated graphic while recording is taking place. DOC | V4.5 | 2010.09...
5.24 Advanced Mode: Alarm Connections You can select how the VOT-320 responds to an alarm. In the event of an alarm, the camera can automatically connect to a pre-defined IP address. You can enter up to ten IP addresses to which the VOT-320 will connect in sequence in the event of an alarm, until a connection is made.
Page 54
| Configuration using a Web browser VOT-320 Connect on alarm Select On so that the VOT-320 automatically connects to a predefined IP address in the event of an alarm. By setting Follows input 1 the camera maintains the connection that has been automatically established for as long as an alarm exists on alarm input 1.
Page 55
NOTICE! Please note that the SSL encryption must be activated and configured at both ends of a connection. This requires the appropriate certificates to be uploaded onto the VOT-320 (see Section SSL certificate, page 79). You can activate and configure encryption of the media data (video and metadata) on the Encryption page (see Section 5.38 Advanced Mode: Encryption, page 77).
VOT-320 5.25 Advanced Mode: VCA The VOT-320 contains an integrated video content analysis (VCA), which can detect and analyze changes in the signal using image processing algorithms. Such changes can be due to movements in the camera's field of view.
Click the Load... button to load a saved profile. A new window opens in which you can select the profile file and specify where to save the file. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Page 58
NOTICE! On the LIVEPAGE Functions page, you can also enable additional information overlays for the LIVEPAGE (see Section 5.14 Advanced Mode: LIVEPAGE Functions, page 38). DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 59
With a low value, it is necessary for changes to occur simultaneously in a large number of sensor fields to trigger an alarm. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Advanced Mode: VCA Scheduled This configuration allows you to link the created VCA profile with the days and times at which the video content analysis is to be active. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 61
Click the date you wish to delete. Click OK. The item will be deleted from the table and the window will close. The process must be repeated for deleting additional days. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
For more information, please see the Alarm Task Script Language document and the RCP+ documentation. You can find these documents on the product CD supplied (see Section 3.1 Parts included, page 10). DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
As an alternative to automatic connecting, alarm states can also be documented by e-mail. In this way it is possible to notify a recipient who does not have a video receiver. In this case, the VOT-320 automatically sends an e-mail to a previously defined e-mail address. Send alarm e-mail Select On if you want the camera to automatically send an alarm e-mail in the event of an alarm.
Page 64
Test e-mail You can test the e-mail function by clicking the Send Now button. An alarm e-mail is immediately created and sent. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Script successfully parsed. is displayed over the text field. If it was not successful, an error message will be displayed with further information. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
VOT-320 5.31 Advanced Mode: Alarm Inputs You can configure the alarm inputs of the VOT-320. Alarm input Select N.O. if the alarm is to be triggered when the contact closes. Select N.C. if the alarm is to be triggered when the contact opens.
Page 67
Special characters are not supported by the system's internal management. Trigger relay Click the button to trigger the relay manually (for testing or to operate a door opener, for example). Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
NOTICE! If the VOT-320 is working in multicast mode (see Section 5.36 Advanced Mode: Multicast, page 75), the first remote location to establish a video connection to the camera is also assigned the transparent data connection. However, after about 15 seconds of inactivity the data connection is automatically terminated and another remote location can exchange transparent data with the camera.
5.34 Advanced Mode: Network The settings on this page are used to integrate the VOT-320 into an existing network. Some changes only take effect after the camera is rebooted. In this case, the Set button changes to Set and Reboot.
Page 70
IP address is assigned, it is retained each time the system is rebooted. IP address Enter the desired IP address for the VOT-320 in this field. The IP address must be valid for the network. Subnet mask Enter the appropriate subnet mask for the selected IP address here.
Page 71
You can specify a higher MSS value for a connection to the iSCSI system than for the other data traffic via the network. The potential value depends on the network structure. A higher value is only useful if the iSCSI system is located in the same subnet as the VOT-320. Enable DynDNS DynDNS.org is a DNS hosting service that stores IP addresses in a database ready for use.
Page 72
Only use this function when necessary and no more than once a day, to avoid the possibility of being blocked by the service provider. To transfer the IP address of the VOT-320, click the Register button. Status The status of the DynDNS function is displayed here for information purposes.
Some changes only take effect after the camera is rebooted. In this case, the Set button changes to Set and Reboot. Make the desired changes. Click the Set and Reboot button. The VOT-320 is rebooted and the changed settings are activated. SNMP The VOT-320 supports the SNMP V2 (Simple Network Management Protocol) for managing and monitoring network components, and can send SNMP messages (traps) to IP addresses.
Page 74
The RADIUS server must also contain the corresponding data. To configure the camera, you must connect the VOT-320 directly to a computer. This is because communication via the network is not enabled until the Identity and Password parameters have been set and successfully authenticated.
In addition to a 1:1 connection between an encoder and a single receiver (unicast), the VOT-320 can enable multiple receivers to receive the video signal from an encoder simultaneously. The device either duplicates the data stream itself and then distributes it to multiple receivers (Multi-unicast) or it sends a single data stream to the network, where the data stream is simultaneously distributed to multiple receivers in a defined group (Multicast).
You can select how file names will be created for the individual images that are transmitted. – Overwrite The same file name is always used and any existing file will be overwritten with the current file. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Advanced Mode: Maintenance Firmware The VOT-320 is designed in such a way that its functions and parameters can be updated with firmware. To do this, transfer the current firmware package to the camera via the selected network. It will then be automatically installed there.
Page 78
| Configuration using a Web browser VOT-320 In this way, a VOT-320 can be serviced and updated remotely without a technician having to change the installation on site. You obtain the current firmware from your customer service or from the download area at www.boschsecurity.com.
You can upload the SSL certificate, comprising one or multiple files, onto the VOT-320. If you wish to upload multiple files onto the VOT-320, you must select them consecutively. NOTICE! The certificate must be created in the format *.pem so that it can be accepted by the camera.
You can select all required text on this page with the mouse and copy it to the clipboard with the [Ctrl]+[C] key combination, for example if you want to send it via e-mail. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
The VOT-320 offers a variety of configuration options. You should therefore check that it is functioning correctly after installation and configuration. The function test is the only way to ensure that the VOT-320 operates as expected in the event of an alarm.
Operation Operation with Microsoft Internet Explorer A computer with Microsoft Internet Explorer (version 7.0 or higher) can receive live images from the VOT-320, control a pan/tilt and replay stored video sequences. System requirements – Computer with Windows XP or Windows Vista operating system –...
Page 83
Operation | en Establishing the connection Before you can operate the VOT-320 within your network, it must have a valid IP address for your network and a compatible subnet mask. The following default address is preset at the factory: 192.168.0.1 Start the Web browser.
If you do not connect, the camera may have reached its maximum number of connections. Depending on the unit and network configuration, each VOT-320 can have up to 25 Web browser connections or up to 50 connections via Bosch Video Client or Bosch Video Management System.
Page 85
Control options for peripherals (for example a pan/tilt) depend on the type of unit installed and on the configuration of the VOT-320. If a controllable unit is configured and connected to the VOT-320, the controls for the peripheral are displayed next to the video image.
Page 86
(see Section 5.14 Advanced Mode: LIVEPAGE Functions, page 38). Triggering relay You can switch connected units using the relays in the VOT-320 (for example lights or door openers). ...
(see Section Allow local recording, page 39). Click the icon to start recording. The storage location depends on the configuration of the VOT-320 (see Section Path for JPEG and video files, page 39). A red dot in the icon indicates that recording is in progress.
Export to FTP button. Click Export to FTP to send the selected recordings to the FTP server. The information below the button allows you to monitor the export. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 89
Use the slide control below the time bar to control playback direction. Drag the rectangle to the right for fast forwarding the playback. Drag it to the left for rewinding. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Hardware connections between video servers A VOT-320 can be used as a sender and a compatible hardware decoder (such as the VIP XD) with a connected monitor as a receiver using an Ethernet network connection. In this way it is possible to cover long distances without the need for major installation or cabling work.
Page 91
Start the terminal program and enter the command 4 in the main menu to switch to the Rcp+ menu. In the Rcp+ menu, enter command 3 to deactivate automatic connection. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Windows operating systems. It is primarily designed for decoding video, audio and control data received from a remote sender. There are many options available for operation and configuration when using a VOT-320 with Bosch Video Client. Please refer to the software documentation for more details.
SD slot until the CONNECT LED flashes red (see Section 3.4 Controls and displays on the camera module, page 15). All settings will revert to their defaults. Change the IP address of the VOT-320 if necessary. Configure the camera to meet your requirements.
Export limitations The camera model VOT-320-V xxH with 30 ips frame rate is governed by the United States Export Administration Regulations. When re-selling the VOT-320 the seller is responsible for applying for the required licenses. He commits himself to compliance with applicable export control regulations.
If you are unable to resolve a malfunction, please contact your supplier or systems integrator, or go directly to Bosch Security Systems Customer Service. You can view a range of information about your unit version on the System Overview page (see Section 5.41 Advanced Mode: System Overview, page 80).
Page 96
Active proxy server in network. Create a rule in the local empty fields. computer's proxy settings to exclude local IP addresses. The CONNECT LED Firmware upload failed. Repeat firmware upload. flashes red. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Identification configuration extension. page. LEDs The VOT-320 has LEDs on its camera module that show the operating status and can give indications of possible malfunctions (see Section 3.4 Controls and displays on the camera module, page 15): CONNECT (opening A) Does not light up: VOT-320 is switched off.
VOT-320 Processor load If the VOT-320 is accessed via the Web browser, you will see the processor load indicator in the top left of the window next to the manufacturer's logo. You can obtain additional information to help you when troubleshooting or fine tuning the unit.
VOT-320 Appendix | en Terminal blocks The VOT-320 offers three pairs of terminal blocks arranged in an upper (U) and lower (L) row: – X-block: 2-pin blocks for power supply and window defroster – Y-block: 5-pin blocks for PT control –...
Page 100
Relay output 2 Input alarm 1 Input alarm 2 Connect each alarm input to a ground contact (GND) on the upper 6-pin terminal block when connecting alarm inputs. DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Communication with terminal program Data terminal If a VOT-320 cannot be found in the network or the connection to the network is interrupted, you can connect a data terminal to the VOT-320 for initial setup and setting of important parameters. The data terminal consists of a computer with a terminal program.
Page 102
102 en | Appendix VOT-320 Assigning an IP address Before you can operate a VOT-320 in your network you must first assign it an IP address that is valid for your network. The following default address is preset at the factory: 192.168.0.1 Start a terminal program such as HyperTerminal.
Corporation not be used in advertising or publicity pertaining to distribution of the software without specific, written prior permission. This software is based in part on the work of the Independent JPEG Group. Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
DNS hosting service that works according to RFC 2845 and stores the IP addresses of its clients in a database, ready for use Flat-field correction; internal mechanism in thermal IP camera VOT-320 for periodically improving image quality. Field Of View, area covered by the picture angle of an optical device...
Page 107
Storage over IP process for storage networks; specifies how storage protocols are operated over IP ISDN Integrated Services Digital Network JPEG An encoding process for still images (Joint Photographic Experts Group) kbps Kilobits per second, the actual data rate Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Page 108
The lower the QP value, the higher the encoding quality. QVGA Quarter Video Graphics Array, video format with 320 × 240 pixels DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 109
UDP. Similarly, control points can search the network for UPnP devices and make them accessible. Uniform Resource Locator Unshielded Twisted Pair Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Page 110
See Wide Area Network WFOV Wide Field Of View, see FOV Wide Area Network A long distance link used to extend or connect remotely located local area networks DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 112
Relay outputs 20 Unit date 35 Remote control 13 Unit reset 93 Repair 9 Unit time 29 Replay 88 URL 25 Reset 15 User name 28 Router 76 DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Page 113
VOT-320 Index | en 113 Video content analysis 56 Video output 16 Video sensor 56 VRM 45 Watermarking 37 Window defroster 16 Bosch Sicherheitssysteme GmbH Installation and Operating Manual DOC | V4.5 | 2010.09...
Page 114
114 en | Index VOT-320 DOC | V4.5 | 2010.09 Installation and Operating Manual Bosch Sicherheitssysteme GmbH...
Need help?
Do you have a question about the VOT-320 and is the answer not in the manual?
Questions and answers