en | Configuration using a Web browser
5.31

Advanced Mode: Alarm Inputs

You can configure the alarm inputs of the VOT-320.
Alarm input
Select N.O. if the alarm is to be triggered when the contact closes. Select N.C. if the alarm is
to be triggered when the contact opens.
Name
You can enter a name for each alarm input, which is then displayed below the icon for the
alarm input on the LIVEPAGE if configured correctly (see Section 5.14 Advanced Mode:
LIVEPAGE Functions, page 38). You can also use the name in the Forensic Search program
function as a filter option for quick search in recordings.
CAUTION!
Do not use any special characters, for example &, in the name.
Special characters are not supported by the system's internal management.
5.32

Advanced Mode: Relay

You can configure the switching behavior of the relay outputs. For each relay, you can specify
an open switch relay (normally closed contact) or a closed switch relay (normally open
contact).
You can also specify whether an output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state.
You can select different events that automatically activate an output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.