KEYPAD CONFIGURATION MODE

This section will focus on configuring the GEM-RP1CAe2 Keypad. If there is more than one keypad in the system, only Keypad No. 1
may be used for programming.

KEYPAD INSTALLATION

The GEM-RP1CAe2 keypad must be assigned an address number (1–15) anthrough the following configuration procedure (see
CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be
used; only 1 is required for a single-area Commercial Burglary installation.
GEM-RP1CAe2 - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a PGM output.
A GEM-RP1CAe2 is recommended for use as Keypad #1.

CONFIGURING THE KEYPADS

A total of up to 15 keypads may be connected to the panel.
Configuring the GEM-RP1CAe2 Keypad
Each GEM-RP1CAe2 keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address; (d)
compatibility number; (e) EZM address; and (f) zone response.
To enter the GEM-RP1CAe2 Configuration Mode:
1. Move jumper JP5 (located at the upper-right corner of the control panel board) from Pins 1-2 (top two) to Pins
2-3 (bottom two). NOTE: See Wiring Diagram.
2. After about 15 seconds, the display will read "XX OUT OF SYSTEM", where XX indicates the keypad address.
3. Press
11123 A
KEYPAD BEEP
ENTRY SOUNDER
KEYPAD ADDRESS
X
GEM-X255 Installation Instructions
and proceed as follows. (Repeat the following procedure
for all keypads.)
Keypad Tactile Beep
Upon entering the Keypad Configuration Mode, "KEYPAD BEEP ON" will be displayed,
ON
indicating that the tactile beep, which sounds when any button is pressed, is on. To
turn off the tactile beep, press the
on and off).
Press the
button to continue or press the
A
Entry Sounder
ON
To turn off the keypad sounder during entry time, press the
will toggle the tactile beep on and off). Press the
the
C
button to exit.
Keypad Address
If more than one keypad is installed, each must be assigned a unique
01
keypad address (that is, no two keypads may be numbered alike):
!
keypads must be numbered consecutively (missing numbers are not permitted)
!
only Keypad No. 1 may be used for programming.
To assign the keypad number, proceed as follows:
1. Enter the assigned keypad number 01–15, then press the
valid number will be acknowledged by a short
rejected by a long beep.
2. Press the
A
J
J
button (the
C
A
beep; an invalid number will be
button to continue or press the
L
WI1093A 12/01
GEMINI
SYSTEM ARMED
01/01/97 12:00AM
A
1 2
3
D
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
NORMAL
KEYPAD
CONFIGURE
button will toggle the tactile beep
button to exit.
J
J
button (the
button
button to continue or press
J
button to save. A
C
button to exit.
NAPCO Security Systems
NEXT/YES
E
PRIOR/NO
F
AREA
G
R

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gemini gem-rp1cae2

Table of Contents