NAPCO Gemini GEM-X255 Installation Instructions Manual page 34

Control panel/communicator computerized security system
Hide thumbs Also See for Gemini GEM-X255:
Table of Contents

Advertisement

!
Page 34
Blocked View Option for User Codes
User codes can block another code from being viewed by another user. An unblocked code cannot view a blocked code, but a
blocked code can view all codes. The master user code and the dealer program code can view all codes.
Burglary Lug (Lug E10)
Lug E10 (BURG.) will go to about 1Vdc when the Burglary Output is tripped. This lug is intended for connection to UL-listed
devices rated 5mA maximum and capable of operating over the voltage range of 8-13.0Vdc (12V, special application). Use Napco Part
No. WL1 for connection.
Burglary Output See Alarm Outputs
Bus Failure
Communication failure on the 4-wire bus will cause a system trouble and a report to the central station. Program System Trouble
Reports and Report Codes for the 4-Wire Bus.
Bypass Faulted Zones
If programmed, pressing the
Zones) that are also programmed for Selective Bypass. The message, "BYPASSED ALL ZONE FAULTS" will display.
Call Waiting See Disable Call Waiting
Callback-Method Download
Answering Machine Pickup Without Line Seizure
Disable Callback Download (Required for UL installations)
Disable Answering Machine Download (Required for UL installations)
Disable Function-Mode Download
Number of Rings Before Pickup
Data may be downloaded remotely to the panel after a programmed number of rings (3 to 15) and a control-panel confirmation
callback. Program the number of rings; if not programmed, the panel will pick up after 15 rings.
This method will accommodate an answering machine at the site. (Disable Answering Machine Download must not be
programmed.) The answering machine will pick up on its programmed number of rings, as usual. The panel will then listen for the
signal from the PCD3000 software and seize the line from the house phones as well as the answering machine and the connection will
subsequently be established. Note: The number of rings programmed into the panel must exceed that of the answering machine.
Program Disable Callback Download to prevent unauthorized downloading to an unattended panel. Program Disable Answering
Machine Download to inhibit downloading to a telephone connected to an answering machine. Program Disable Function-Mode
Download to prevent downloading at the keypad.
Cancel Next Test Timer Report on Any Report See Test Timer
Cancel; Cancel Code; Cancel Report to Telco 3; Cancel Window Duration
CANCEL is the preventing of a report from being sent by entering a user disarm code. If the area is disarmed during the "Pre-Alarm
Warning", then no report will be sent and no messages will be displayed at the keypad. If the area is disarmed during the Abort-Delay,
then an "Alarm Canceled' will be displayed at the keypad and no report will be sent. If the area is disarmed during or within the Cancel
Window Duration, then an "Attempting to Cancel" will be followed by an "Alarm Canceled" for a successful cancellation. Otherwise,
the report had been sent and will be responded appropriately to by the Central Station. Cancel must be provided with a Central Station
Telephone Number, proper Subscriber ID Numbers and a valid Cancel Code to Telco 3. A Cancel Window is the duration that the
system will attempt to cancel a report, after the report is sent.
Chime (Displays "MONITOR" on GEM-RP2ASe2 Keypads)
This annunciator feature may be used on any zone to sound a tone at the keypad while disarmed when the zone is faulted.
Access the ACTIVATE CHIME function to enable or disable the Chime Mode from the keypad. This feature is programmable by zone
and for duration of tone (see Time Selection). A time (in ¼ seconds) must be programmed for the chime to function.
Chime 2 (Displays "MONITOR" on GEM-RP2ASe2 Keypads)
For a distinct pulsating "Chime Zone" tone, program the zone for Chime 2. This feature allows zones to have distinctive annunciator
chime to identify the door(s) or zone(s). "Chime" must be activated on any keypad for all area keypads to chime.
Chime on E4 Lug
The E4 Lug can now serve as an output that follows the chime sounder. This can be used where a remote sounder is needed to
follow the keypad sounder. This feature can be found on the Options page of the PCD software, or you can program a bit value of 2 in
the right hand side of location 2420 [!] [2].
X
GEM-X255 Installation Instructions
and
buttons simultaneously will bypass all zones in trouble (except Fire and PIR
G
B
WI1093A 12/01
L
NAPCO Security Systems

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gemini gem-rp1cae2