NAPCO Gemini GEM-X255 Installation Instructions Manual page 38

Control panel/communicator computerized security system
Hide thumbs Also See for Gemini GEM-X255:
Table of Contents

Advertisement

!
Page 38
Don't Clear Aux. Relay with Arm/Disarm
Used in conjunction with Key-Fob Option "C" above to prevent a disarm from resetting the Aux. Relay.
"E" Lugs (E3, E5, E7, E9, E10, E11, E14, E18, E19, E22)
E9 - See Fire Lug
E10 - See Burglary Lug
E19 - See Veri-Phone: Silence All Outputs During Audio Session
E22 - Common terminal for Reset Relay. Use Napco Part No. WL1 for field wiring.
Easy Arming
Permits quick arming by simply pressing the
Keypad Features). Disarming still requires entry of a valid user code. Do not program Easy Arming in UL installations. If closings are
reported, Easy Arming will report as User 99.
Easy Setup for RF Only
Removes all EZMs automatically programmed in the menu-driven Keypad Program Mode. This must be the last step in the
programming menu. Access Location 4090, then press the
Enable Burg Output Warning On Entry
Causes the Burglary Output to "chirp" if the entry door is opened within 60 seconds after exit time has elapsed. This feature may
be useful in cases where a keypad is not within audible range to remind a user to disarm if inadvertently exiting after exit delay has
expired.
Enable Exit Delay Restart See Entry/Exit Delay
Enable Line Fault Test
Telco Line Test Delay
Enable Line Fault Test will cause the panel to monitor the phone line. A failure will display as "E08-00 TELCO LINE1 FAIL". Program this
system trouble to activate the Burglary Output.
If a time is entered in Telco Line Test Delay, the line will be tested for the programmed time before a system trouble is activated.
A minimum of 30 seconds is recomm
Enable Local Alarm on First Zone "AND" Trip See Zone ANDing (Do not program in UL installations.)
Enable Reporting to PC Preset
This feature allows a PC computer with Quickloader Software to function as a receiver. If programmed, all alarms sent to
Telephone No. 1 will be sent to PC PRESET as well (regardless of whether or not transmissions to Telephone No. 1 were successful).
PC PRESET must be in its Standby mode for this feature to operate.
Enable User Code by Area See User Codes/Authority Levels/Access Bytes
Entry/Exit Delay
Entry/Exit 1; Entry/Exit 2
Entry Relay
Enable Exit-Delay Restart
Delays permit exit and entry through the Entry/Exit Zone(s) after the system is armed without setting off an immediate alarm.
Entry delay allows the user time to enter and disarm the panel. Exit delay allows the user to leave the premises after the panel has
been armed. Unless the keypad has been configured otherwise, the sounder will come on and will pulse during the last 10 seconds of
entry delay to remind the user to disarm.
Two individually-programmable entry-delay times are provided to accommodate different entry zones. If two or more Exit/Entry
Zones are entered in succession, the delay programmed for the last Exit/Entry Zone entered will take precedence over all others.
Exit-Delay time and Entry-Delay time may each be programmed for up to 255 seconds (4 minutes). See Time Selection.
An external relay may be programmed to trip upon entry (see Programming Manual: Relay Event ID Codes, Area Entry Relays),
and remain on for a programmed duration.
If the system has been armed with Exit-Delay Restart enabled, when the exit door is opened and then closed, the programmed
exit delay will restart at 60 seconds. Thus, if a long exit delay is programmed, it will be reduced to 60 seconds after exiting, yet still
allow reentry before entry time starts. If re-entry occurs within that 60 seconds, exit delay will restart once again (and only once again)
at 60 seconds.
If re-entry occurs within 60 seconds after exit delay has expired, the alarm will sound a 2-second warning (with the entry sounder)
to remind the user to disarm. (Exit-Delay Restart may be useful in reducing false alarms caused by a user who re-enters the premises
shortly after exiting.)
Note: In UL installations, maximum exit delay is 60 seconds; maximum entry delay is 45 seconds. In UL Mercantile installations,
maximum entry delay is 60 seconds.
Entry delay may be canceled by pressing the
disarming. (When armed with Instant protection, an "I" will appear at the right side of the display.)
X
GEM-X255 Installation Instructions
J
button. Each keypad may be individually programmed for Easy Arming (see
J
button.
ended.
F
button prior to arming, however it will be restored automatically upon
WI1093A 12/01
L
NAPCO Security Systems