NAPCO Gemini GEM-X255 Installation Instructions Manual page 43

Control panel/communicator computerized security system
Hide thumbs Also See for Gemini GEM-X255:
Table of Contents

Advertisement

WI1093A 12/01
Keypad (Police) Panic
Keypad Fire Panic See Fire
Remote Panic
The Panic Zone is always a 24-Hour Zone. Each keypad is individually selectable for keypad panics (see Keypad Features). If
Keypad Panic is programmed for a keypad, police panic is activated by simultaneously pressing the
Keypad Aux. is programmed, pressing
Fire is programmed, pressing
A remote panic button may be connected to a GEM-RP2ASe2 Keypad. Splice the two white wires from the keypad to a
normally-open momentary-contact pushbutton. Additional panic buttons may be wired in parallel with the first. If remote panic will not
be used, insulate both white wires, as a short across them will cause a panic alarm. (In UL installations, remote-panic buttons must be
located within 3 feet of the keypad, with no intervening walls or barriers.
Power-Up Delay
If programmed, power-up will be delayed for 5 minutes to allow devices such as PIRs time to stabilize (warm up). This will prevent
false alarms when ac power is restored after a long power outage and the backup battery is discharged.
Pre-Alarm Warning (Not for UL applications)
Programmable by zone, this feature will cause an alarm to sound only at the keypad for the duration of the programmed abort
delay (see Abort Delay; Time Selection). After the delay has elapsed, the alarm output will activate and a report will be sent. Note: If
no Abort Delay time is programmed, Pre-Alarm Warning time will be 10 seconds.
Pre-Dial Delay
A Pre-Dial Delay may be used whenever a delay is required before dialing. It may be required when programming Dial-Tone
Detection, which causes the communicator to wait before it attempts to detect a dial tone (see Dial-Tone Detection). Certain telephone
exchanges send a nonstandard dial tone that the communicator may not be able to detect. With these nonstandard exchanges, it is
possible to program Pre-Dial Delay rather than Dial-Tone Detection. This will cause the communicator to wait for a predetermined
period of time before dialing rather than look for a nonstandard dial tone.
Contact the telephone-equipment supplier to find out how long a delay is required before dialing. Select Pre-Dial Delay by
programming one "D" for each 4-second delay required immediately before the telephone number. Note: In UL installations, do not
program more than one "D" before the telephone number.
See Backup Report on Telco 2; Report Telco 3 (Double or Split Reporting). Also see Access Number for Outside Line; Telephone
Numbers.
Priority Area Arming
Prevents area arming if the alternate Priority Area has not yet been armed.
Priority Zone (Required for all zones in UL installations.)
A zone that will prevent arming if in trouble. If an attempt is made to arm, the sounder will come on and "ZONES NOT NORMAL/CAN'T
ARM" will be displayed for 4 seconds. The keypad may be reset by simply pressing the
be corrected before the panel can be armed.
Any zone may be selected as a Priority Zone. A zone in trouble that is neither a Priority Zone nor an Auto-Bypass Zone will cause
an alarm on arming.
Priority Zone with Bypass
A Priority Zone that will permit arming if the priority condition is bypassed. If the system is so programmed, the zone will
auto-bypass and (optional) the condition will be reported to a central station.
As above, if an attempt is made to arm, the sounder will come on and "ZONES NOT NORMAL/CAN'T ARM" will be displayed. To reset the
J
keypad, press the
button; the display will read "ZONE FAULTS". To arm the panel, press the
Any zone not selected as a Priority Zone may be programmed as a Priority Zone with Bypass.
Pulse Burglary Output See Alarm Outputs
L
NAPCO Security Systems
8
and
G
and
buttons at the same time will activate fire panic.
7
G
buttons simultaneously will trip an auxiliary emergency alarm. If Keypad
J
button. The problem on a Priority Zone must
X
9
and
G
C
button, then enter the User Code.
GEM-X255 Installation Instructions
!
Page 43
buttons. If

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gemini gem-rp1cae2

Table of Contents