Key Used to enable
special functions and
*
options. Press
and
then the corresponding
Special Function num-
ber Option (See Special
Functions, Page 10)
Bypass Key Used to
bypass zones. Press
Bypass and the corre-
sponding zone number,
and then Arm system.
Emergency Keys Press
simultaneously to signal
an emergency condition.
A
A
Press
+
for
Auxiliary Emergency or
P
P
+
for Police Emer-
gency. (Programmable)
Numerical Keys 1-9, 0. Used to enter
User Codes, Zone numbers, etc.
! Key Press to display any present
System troubles. Only available when
System Light is lit. (See System
H
troubles, Page 12)

Keypad Controls and Indicators

Armed Light will light when system is Armed,
W
and will flash when system is in Alarm.
Ready Light will light when all zones are se-
X
cure and system is ready to be Armed.
System Light will light and the Keypad
H
sounder will pulse to indicate that a system trou-
ble is present. (See System troubles, Page 12)
Fire Light will light and the Keypad sounder
I
will pulse to indicate that a fire has been de-
tected in the system.
Power Failure will light and the Keypad
Y
sounder will pulse to indicate the absence of AC
power at the control panel. Call for service.
Zone Lights (1 through 4) will light to indicate
that the corresponding Zone is open, and will
flash to indicate a zone in alarm.
#
Key - (Reset) used to clear miss-entered
codes, reset Alarm Memory, etc..