Receiver Format
The communicator can be programmed to transmit to any standard central-station receiver. A receiver format must be entered for
each telephone number used, but a different format may be assigned to each.
Refer to Backup Report on Telco 2 and Report Telco 3 to determine whether or not Telephones 2 and/or 3 will be programmed.
Call the central station for each telephone number used to confirm the type of receiver in use. Select the receiver format entry for each
telephone number from the following table.
ENTRY
(blank)
1
2
3
4
5
8
9
A
B
C
D
0
*These formats do not use programmable codes, but Event ID Codes to identify the type of zone as follows:
1 – Fire
2 – Panic
3 – Burglary
4 – Holdup
7 – Gas Alarm
8 – Heat Alarm
A – Auxiliary Alarm (keypad displays "0")
B – 24-Hour Auxiliary Alarm
Relay Control (External Relays)
In addition to the three relays provided on the motherboard, up to 24 external relays (8 per RB3008 Relay Module) or X-10
devices (24 per GEM-X10 module) may be controlled from the keypad, by event or by schedule through the use of PCD-Windows
downloading software. Program these outputs to activate by event on PCD-Windows External Relay Control screen, or by schedule on
the Event Scheduler screen.
Relay Follows Zone
External Relays can be programmed to follow an open or shorted zone. On the PCD-Windows External Relay Control screen,
program the External Relay to "follow " an open zone, or to "follow" a shorted zone.
Relay Outputs See Alarm Outputs
Relay / X-10 Mapping
It is possible to have a relay or X-10 device activate for multiple events, with a maximum of 24 events. This allows the relay or
X-10 device to be activated by multiple events or conditions. This is programmed by assigning or mapping events to relay numbers.
PCD3000 must be used to program Relay/X-10 mapping. Referring to the PCD3000 External Relay Control screen, the "Relay /
Entry#" column typically indicates the number of the relay which will accept the commands on that line. However, the "Map" column,
which is used to transfer the function defined on that line to a device on another line.
Remote Panic See Panic Zone
Report Telco 1
Report Telco 3 (Double or Split Reporting)
Alarms, alarm restores, troubles and trouble restores may be selected individually for each zone. Violation of a zone selected to
report will communicate the code(s) selected for that zone to the central station.
Normally, Report Telco 1 is used to report to the central station. Report Telco 3 is used when certain zones will report to a
different receiver (split reporting); Report Telco 1 and Report Telco 3 are both used on the same zone to report to two receivers
X
GEM-X255 Installation Instructions
RECEIVER FORMAT
DATA FREQ. (Hz)
Ademco, Silent Knight Slow
Sescoa, Vertex, DCI,
Franklin Fast
Radionics Fast
Silent Knight Fast
Radionics, DCI, Franklin
Slow
Universal Hi-Speed
Radionics BFSK
4/3/1*
Radionics Modem 2*
SIA*
Point ID*
Express (Touch-tone 4/2 Format)
DUTY CYCLE
(ON/OFF)
1900
60/40mS
1800
30/20
1850
13/12
1900
40/30
1800
60/40
1850
30/20
Modem Formats
Radionics Modem IIe
WI1093A 12/01
INTERDIGIT TIME
600mS
800
400
560
600
350
L