WI1093A 12/01
Areas
Zone Area 1-Zone Area 8
Priority Area Arming
Although the default program will automatically set up Zones 1 through 8 for Zone Area 1, the panel may be partitioned into eight
areas. Each zone must be assigned to at least one area. At least one zone must be assigned to Area 1. If a burglary zone is selected
for both areas, that common zone will not arm until both areas are armed. If any zone disarms, the common zone will disarm.
In a multiple-area system, be sure to also program:
Enable User Code by Area (see User Codes/Authority Levels);
Keypad Area Assignments
Bell Control (determines which bells an area may silence);
Subscriber Opening/Closing ID Numbers and Event ID Numbers (if reporting);
System Trouble Subscriber ID Number
If Priority Area Arming is selected, the Priority Area must be armed before the Arming Area can be armed.
Arm Lug (Lug E4)
Lug E4 (ARM) will go to approximately 1Vdc when all areas in the system are armed. This lug may be used for auxiliary
equipment. (For use, refer to the instructions furnished with the device.)
Auto Bell Test on Arming (Required for UL Mercantile installations.)
This will activate the Burglary Output briefly 10 seconds after the area is armed. If the alarm does not sound, the device may be
defective.
Auto-Bypass (Do not program for UL installations.)
Auto-Bypass Re-entry
Zones programmed for Auto-Bypass will be bypassed (automatically removed) if in trouble when arming. A momentary beep will
sound at the keypad to warn that the system has been armed without the protection of the auto-bypassed zone. (Note that the
exit/entry door must be closed before arming, otherwise the Exit/Entry Zone will be auto-bypassed.) Note: A zone in trouble that is not
programmed for Auto-Bypass will cause an alarm on arming after a 10-second arming delay.
If Auto-Bypass Re-entry is selected, securing a zone that is programmed for Auto-Bypass, while armed, will cause that zone to
re-enter the system in an armed state.
Auto Disarm Rearm Delay
If the panel was auto-disarmed on schedule and a rearm delay is programmed (see Time Selection), the panel will automatically
rearm after the delay if no activity has been detected.
Automatic Interior Bypass
Interior 1 Normally Bypassed must also be programmed for this feature to work. This feature will cause all Interior-1 Zones to
automatically provide protection if the Exit/Entry doors are opened during the exit-delay period. If the
armed, exit delay will restart and the Exit/Entry doors may be opened to permit someone to exit (while others remain on the premises)
without causing an alarm.
Aux. Output Chirp on Key-Fob Arming
This feature will cause a 1-chirp indication on arming and 2-chirp indication on disarming. Connect steady input (burglary) of
external siren driver to the panel's Auxiliary Alarm Output. Note: Do not use an external voice siren driver.
Auto-Reset
Auto-Reset After Burglary Output Timeout
If a zone detects an alarm condition and is selected for Auto-Reset, it will automatically rearm itself as soon as the alarm condition
is cleared. Auto-Reset may be delayed to occur after the Burglary Output timeout period by selecting Auto-Reset After Burglary Output
Timeout and Auto-Reset. Zones that are not programmed for Auto-Reset will not be capable of signalling another alarm until (a) the
cause of the alarm has been corrected and (b) the control panel is disarmed. Also see Swinger Shutdown.
Auxiliary Relay See Alarm Outputs
Backup Report on Telco 2
If Backup Reporting is selected and the communicator does not reach the first telephone number after two attempts, seven
attempts will be made to reach the second telephone number. Enter Subscriber Identification Numbers for Telephone 2 and other
information required for Telephone 2. Also program Backup Report on Telco 2. Any zone programmed to report to Telco 1 will backup
report to Telco 2. Note: Subscriber Identification Numbers for both Telephones 1 and 2 must be entered, even if they are the same
Battery
12Vdc standby power source in the control panel is used to provide backup protection in the event of a power loss. The battery is
an integral part of the system and must be installed, even if ac power is present. Change the battery every 5 years or as required.
Bell Control
In any system, the ability to silence any combination of alarm devices (outputs) initiated from any area. Bell Control must be
programmed for all systems to be able to silence an alarm. For example, in a two-area system, each area could be programmed to
silence only those alarms initiated within its own area; or both areas could be programmed to silence an alarm initiated from either
area.
L
NAPCO Security Systems
E
X
GEM-X255 Installation Instructions
!
Page 33