List Of Compatible Equipment; Supported Sounder Types & Their Applications - Zeta NPAD Installation Manual

Analogue addressable fire alarm control panel
Table of Contents

Advertisement

PREMIER AD INSTALLATION MANUAL.

2. LIST OF COMPATIBLE EQUIPMENT

Stock No
Product Code
37-150
PR-AD
37-155
PREP-AD
80-110
FEAI2000
80-120
FEAO2000
80-130
FEAH2000
80-131
FEAHH2000
80-140
FEAOH2000
80-150
FECO2000
80-050
FE-CB
80-080
FEA-RB
80-090
FE-IB
80-100
FEA-SB
80-101
FEA-ISB
43-001
ZT-MCP/AD
43-022
ZT-MCP/AD/WP
48-100
ZIU
48-105
ZIOU
48-110
ZSCC
48-115
ZT-ZM
42-007
ZAMT
42-008
ZAMD
42-030
ZAST
48-020
ZTA/LE2
47-055
ZTA-FR50
47-056
ZTA-FR100
47-110
FE+50/AD
42-001
ZMT/8
42-002
ZMD/8
42-004
ZST/8
42-005
ZIDC/10R
42-011
ZFL2RR
42-013
ZLT/8RR
41-003
ZTB6B/24
41-005
ZTB8B
2.1 SUPPORTED SOUNDER TYPES & THEIR APPLICATIONS
The Premier AD supports 4 general sounder types; conventional, addressable, addressable sounder controller,
and associated sounders. All types have advantages & disadvantages.
Sounder type
Advantage
Conventional
Wide range of devices
Devices tend to be cheaper.
Immediate start / stop
No quiescent current
Addressable
No Extra Cabling
Sounders can be configured as zonal
Associated
No Extra Cabling
(sounder-
Doesn't occupy Device Address
base)
Can have more than 32 per loop
Addressable
Wide range of devices
Sounder
Devices tend to be cheaper.
Circuit
Can add many sounder circuits to system
Controller
Sounder circuit can be set as zonal
Approved Document No: GLT.MAN-105
Issue : 1.02
Authorised: GH
Device
Premier AD Fire Alarm Panel
Premier AD Repeater
Fyreye Addressable Ionisation Detector
Fyreye Addressable Optical Detector
Fyreye Addressable Heat Detector
Fyreye Addressable High Temperature Heat Detector
Fyreye Addressable Multi-Point Detector
Fyreye Addressable Carbon Monoxide Detector
Fyreye Common Base
Fyreye Addressable Relay Base
Fyreye Addressable Loop Isolator Base
Fyreye Addressable Sounder Base
Fyreye Addressable Isolator Sounder Base
Zeta Addressable Call Point
Zeta Weatherproof Addressable Call Point
Zeta Input Unit
Zeta Input Output Unit
Zeta Sounder Control Module
Zeta Zone Monitor Unit
Zeta Addressable Maxitone Sounder
Zeta Addressable Miditone Sounder
Zeta Addressable Securetone Sounder
Zeta Addressable Remote Led Indicator
Fyreye Addressable Reflective Beam Detector 50m
Fyreye Addressable Reflective Beam Detector 100m
Fyreye Plus Addressable Aspiration Detector
Zeta Conventional Maxitone Sounder
Zeta Conventional Miditone Sounder
Zeta Conventional Securetone Sounder
Zeta Conventional Megatone Sounder
Zeta Conventional Flasher
Zeta Conventional Flasher Sounder
Zeta Conventional 6" Bells
Zeta Conventional 8" Bells
Date: 15/03/2004
Software:31/3/04 & LC6
Disadvantage
Needs extra cabling
Always configured as common sounders
Tends to be more expensive
Maximum 32 per loop for quick start/stop
Quiescent current high
Uses device address.
4-8 second start & stop time.
Always configured as common sounders
Needs detector present to operate.
Does not operate during sounder test mode
Needs Extra Cabling.
Needs External PSU
Maximum 32 per loop for quick start/stop
Quiescent current high
Uses device address.
PAGE 4