5.
Remove the fuser web oiler motor assembly mounting screws and remove the
assembly.
Note: When you reinstall the web oiler motor assembly, pull the excess cable, twist,
install a cable tie, and route the cable down into the printer.
Note: Make sure the motor cable is routed away from gears (B).
5060-XXX
4-19
Repair Information