PRODUCT DATA SHEETS
Base Grille Water
Filtration
System
Model WF-LC200V Capacity 200 Gallons (757 Liters)
Model WF-NLC120V Capacity 120 Gallons (454 Liters)
System tested and certified by NSF International against NSP/ANSI
Standard 53 for the reduction of Lead, Mercury, Benzene,
p-dichlorobenzene,
Cysts, Turbidity, Asbestos, Endrin,
O-Dichlorobenzene,
Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene
and against NSF/ANSI Standard 42 for the reduction of Chlorine Taste
and Odor and Particulate Class I.
This system
has been tested according
to ANSI/NSF
42/53 for the reduction
of the substances
listed below. The concentration
of the
indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the permissible
limit for water
leaving the system, as specified
in ANSI/NSF
42/53
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
I Chlorine Taste/Odor
->50%
1,9 mg/L
2,0 mg/L ± 10%
/ 0,12 mg/L
0,08 mg/L
>75%
>75%
I
Particulate Class I*
->85%
5,300,00O/mL
I
99.7%
I
99.0%
At least 10,000 partictes/m H 5O,00O/mL**
15,725/mL
i
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.01 mg/L
0,14 mg/U
0,15 mg/L ± 10%
0,001 mg/L
0,001 mg/L
99.29%
99.29%
Lead: @ pH 8.5
0.01 mg/L
0,15 mg/U
0,15 mg/L
± 10%
0,001 mg/L
0,001 mg/L
99.32%
99.32%
Mercury: @ pH 6.5
0.002 mg/L
0,0058 mg/L
0,006 mg/L ± 10%
0,0005 mg/L
0,0003 mg/L
91.37%
94.82%
Mercury: @ pH 8.5
0.002 mg/L
0,0055 mg/L
0,006 mg/L
± 10%
0,0013 mg/L
0,0005 mg/L
76.36%
90.90%
Benzene
0.005 mg/L
0.0153 mg/L
0,015 mg/L ± 10%
0.0036 mg/L
0,0014 mg/L
76.47%
90.84%
p-dichlorobenzene
0.075 mg/L
0.215 mg/L
0.225 mg/L ± 10%
0.0037 mg/L
0.0010 mg/L
98.27%
99.52%
Asbestos
99.0%
842 x 10
10to
108fibers/L r*
1.6 x 10 mg/L
1.6 x 107 mg/L
99.81
99.81%
Cysts*
99.95%
165,500/mL
50.000/L min.
1 mg/L
1 mg/L
99.99%
99.99%
Turbidity
0.5 NTU
11.75 NTU
11 ± 1 NTU
036 NTU
022 NTU
96.76%
96.12%
Endrin
0.002
00056
0006 ± 10%
00007
00004
87.50
92.85
O-Dichlorobenzene
0.60
1.84
1.8 ± 10%
0.33
0.071
82.06
96.14
Toxaphene
0.003
0.0143
0.015 ± 10%
0.001
0.001
93.00
93.00
Ethyl Benzene
0.70
2.00
2.1 ± 10%
0.60
0.169
70.00
91.55
1,2,4-trichlorobenzene
0.07
0.232
0.21 ± 10%
0.0025
0.0007
98.92
99.69
Test Parameters:
pH = 7.5 ± 0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure
= 60 psig (413.7 kPa). Temp. = 63°F
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Model
WF-LC2OOV:
The filter monitor
system
measures
the
amount
of water that passes through
the filter and alerts you to
replace the filter. When 90% of the filter's rated life is used, the
filter indicator
light changes
from green to yellow. When 100% of
the filter's rated life is used, the filter indicator
light changes
from
yellow to red, and it is recommended
that you replace the filter.
Use replacement
cartridge
LC200V/NLC120V,
part #9915.
2004
suggested
retail price of $32.99 U.S.A./S49.99
Canada.
Prices
are subject
to change without
notice.
Model
WF-NLCI2OV:
Change the water filter cartridge
every
6-9 months.
Use replacement
cartridge
LC2OOV/NLC120V,
part
#9915. 2004 suggested
retail price of $32.99
U.S.AJ$49.99
Canada.
Prices are subject
to change
without
notice.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters
that may contain
filterable
cysts.
(17.2°C).
Refer to the front cover or "Accessories"
section for the
Manufacturer's
name, address and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0,6 ° - 37.8 ° C)
Service
Flow Rate
0.5 GPM (1.89 L!rain.) @ 60 psi,
Class
I particle size: >0.5 to <1 um
"Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
_These contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
r'Fibers greater than 10 um in length
:_Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark
of NSF International.
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite 106. series

Table of Contents