PRODUCT DATA SHEETS
Cyst Interior Water Filtration System Model WFI-NLCS200/NLCS200
i Tested and certified by NSF international against ANSi/NSF Standard |
42 for the reduction of Chlorine (Class 1)Taste and Odor and against
J
ANSi/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Capacity: 200 gallons (757 liters),
Service flow rate: 0.5 GPM (1.89 L!min.) @60 psi.
Substance
Reduction
U.S. EPA
Average
Maximum
Average
Minimum
%
Average %
NSF Test
Aesthetic
Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Chlorine Taste/Odor
N/A
1.9 mg/L
N/A
0.06 mg/L
N/A
97%
994707
Particulate
N/A
108,667/mL*
N/A
45/mL
N/A
99.96%
994711
Contaminant
U.S. EPA
Average
Maximum
Average
Minimum
%
Average %
NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Cyst
99.95%**
157,750/mL
55/mL
1.0/mL
99.9987%
99.9996%
994710
Turbidity
N/A
26 NTU
0.5 NTU
0.1 NTU
98.9%
99.5%
994710
Lead: @ pH 6.5
0.015 mg/L
0.160 mg/L***
0.011 mg/L
0.001 mg/L
93.5%
99.4%
994708
Lead: @ pH 8.5
0.015 mg/L
0.158 mg/L***
0.011 mg/L
0.001 mg/L
92.1%
99.3%
994709
It is essential that operational, maintenance,
and filter
Refer to the front cover or "Assistance
or Service" section for
replacement requirements be carried out for this product to
the Manufacturer's
name, address and telephone number.
perform as advertised.
Refer to the "Warranty" section for the Manufacturer's
limited
Model NLCS200 Change the cartridge at least every 6-9
warranty.
months. Use replacement cartridge NLCS200, part# 9002.
2002 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or
of unknown
quality without
adequate
disinfection
before
or after the system.
Systems certified
for cyst reduction
may be used on disinfected
water that may contain
filterable
cysts.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8 ° C)
* Test requirement
is at least 100,000 particles/ml
of AC Fine Test Dust.
** Cyst performance
is % reduction based on NSF Standard 53.
*** Test requirement
is 0.15 mg/L _+10%. These contaminants
are not necessarily in your water supply. Performance
may vary based on local water
conditions.
® NSF is a registered
trademark
of NSF International.
22

Advertisement

Table of Contents
loading

This manual is also suitable for:

7930

Table of Contents