Product Data Sheets - Kenmore 2225403 Use & Care Manual

Top-mount refrigerator
Table of Contents

Advertisement

PRODUCT DATA
Cyst Interior Water Filtration System Model WFI-NLCS200/NLCS200
Tested and certified by NSF International
against ANSI/NSF
Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANS/NSF
Standard 53 or the reduct on of Lead, Cysts and Turb d ty.
Capacity: 200 gallons (757 liters),
Service flow rate: 0.5 GPM (189 L/min.) @ 60 psi
Substance
Reduction
U.S. EPA
Average
Maximum
Average
Minimum %
Average %
NSF Test
Aesthetic Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Chlorine Taste/Odor
N/A
1.9 mg/L
N/A
0.06 mg/L
N/A
97%
994707
Particulate
N/A
198,667/mL*
N/A
45/mL
N/A
99.96%
994711
Contaminant
U.S. EPA
Average
Maximum
Average
Minimum %
Average %
NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Cyst
99.95%**
157,750/mL
55/mL
1.0/mL
99.9987%
99.9996%
994719
Turbidity
N/A
26 NTU
0.5 NTU
0.1 NTU
98.9%
99.5%
994719
Lead: @ pH 6.5
0.015 mg/L
0.160 mg/L***
0.011 mg/L
0.091 mg/L
93.5%
99.4%
994708
Lead: @ pH 8.5
0.015 mg/L
0.158 mg/L***
0.011 mg/L
0.091 mg/L
92.1%
99.3%
994709
It is essential that operational,
maintenance, and filter
replacement
requirements be carried out for this product to
perform as advertised.
Model NLCS20O Change the cartridge at least every 6-9
months. Use replacement cartridge NLCS290, part# 9002.
2002 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or
of unknown quality without adequate disinfection
before
or after the system. Systems certified for cyst reduction
may be used on disinfected water that may contain
filterable cysts.
Refer to the front cover or "Assistance or Service" section for
the Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application GuidelinesP_/ater
Supply Parameters
Water Supply
City or Well
Water Pressure
39 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 190°F (0.6° - 37.8 ° C)
* Test requirement
is at least 100,000 particles/ml
of AC Fine Test Dust.
** Cyst performance
is % reduction based on NSF Standard 53.
*** Test requirement
is 0.15 mg/L ± 10%. These contaminants
are not necessarily in your water supply. Performance
may vary based on local water
conditions.